Document # 50075 Rev B 3/13/95
AC Loss Reporting Delay (60) '1' is factory default which causes a 6 hour time
delay for AC loss reporting. Valid entries are 0 to 9 and A to F corresponding to the
following reporting delay times: '1' = 6 hour, '2' = 7 hours, '3' = 8 hours, '4' = 9
hours, '5' = 10 hours, '6' = 11 hours, '7' = 15 hours, '8' = 16 hours, '9' = 17 hours, 'A'
= 18 hours, 'B' = 19 hours, 'C' = 20 hours, 'D' = 21 hours, 'E' = 22 hours and 'F' = 23
hours. '0' entry causes immediate reporting of AC loss.
Host Panel ID (61)
Enter one of the following digits corresponding to the Control Panel in which the
UNI•COM is installed. A correct entry is essential for proper operation.
0 = Unimode 200
1 = Unimode 416
2 = Unimode II
3 = Do not use
4 = Do not use
5 = Do not use
6 = Do not use
7 = Do not use
8 = Do not use
9 = Do not use
Serviceman Code (62-65)
The factory default is 62=6, 63=3, 64=2 and 65=1. The code must be properly
entered to enable the following modes: program, walktest, troubleshoot and type. It
also enables the clear function. The code may be changed. If, however, the code is
changed and then forgotten, the factory default code of 6321 may be restored by
pressing the MODE key followed by A, A, 1, 2, 3 and then pressing [ENTER/
STORE].
Safety Delay Time (66-68)
Factory default is addresses 66=0, 67=0 and 68=0. Do not use.
User Codes (69-98)
Six 4-digit user codes may be programmed. The user is identified at the UCS
receiver by this 4-digit code. In addition, each user code may designate whether or
not the walktest events are transmitted to the UCS when the UNI•COM is used with
a Unimode 200 FACP.
69 - 72 = User 1 Walk Test Code
73 = User 1 Walk Test Transmit Enable
74 - 77 = User 2 Walk Test Code
78 = User 2 Walk Test Transmit Enable
79 - 82 = User 3 Walk Test Code
83 = User 3 Walk Test Transmit Enable
84 - 87 = User 4 Walk Test Code
88 = User 4 Walk Test Transmit Enable
89 - 92 = User 5 Walk Test Code
93 = User 5 Walk Test Transmit Enable
94 - 97 = User 6 Walk Test Code
98 = User 6 Walk Test Transmit Enable
For all User Walk Test Codes, the factory default of FFFF means no user is
identified. Altering the default entries causes the user to be identified. Valid entries
are 0 - 9 and A - F. For the Walk Test Transmit Enable addresses, a factory default
entry of '0' disables the transmission of walktest events, while an entry of '1' enables