Ace Hardware R-30-T7 Water Pump User Manual


 
23833A343
3
IMPORTANT SELECT
CORRECT VOLTAGE
USE COPPER CONDUCTORS ONLY
VOLTAGE SELECTOR
AT REAR OF MOTOR
(USE NEEDLE
NOSE PLIERS)
PULL SELECTOR -
ROTATE - REINSERT
115
230
115V
230V
L2
L1
HIGH
VOLTAGE
LOW
VOLTAGE
VOLTAGE
SELECTOR
TERMINAL BOARD
GRD
UNGROUNDED
LINE
FINDING THE DEPTH OF YOUR WELL
The jet tank system installs differently depending
on the depth of your well. Tie a small but heavy
weight to the end of a piece of string (be sure there is
enough string; some wells are very deep). Lower the
weight into the well until it reaches the bottom. Take up
the slack and mark the string at ground level. Pull the
weight out of the well and measure from the bottom of
the weight to the ground level mark. This is the depth
of your well. Subtract five feet from the depth of your
well. This number should not exceed the maximum
rated depth for your pump. If it does, it will greatly
hinder or prevent the proper operation of the pump.
115V OR 230V OPERATION
Your pump is equipped with one of two types of dual
voltage motors. Follow the instructions to wire the
motor for the proper voltage. The voltage of the pump
must match the voltage of the power supply.
WIRE SELECTION GUIDE
WIRING YOUR PUMP
Remove the cover from the pressure switch. Connect
the bare copper ground to the ground screw in the
pressure switch. Connect the power supply to the
terminals marked "Line" in the diagram below.
NAME
PLATE
AMPS
464
1857
#14
#8
296
1184
189
756
118
475
10.6
5.3
115
230
VOLTAGE
MAX. WIRE LENGTH USING AWG SIZE
#12 #10
STANDARD LINE
PLUG FUSE*
LOW PEAK - CART. TYPE
FUSETRON - CART. TYPE
FUSTAT - PLUG TYPE*
CIRCUIT BREAKER
115V
230V
115V
230V
115V
230V
20 10 12 6-1/4 20 15
FUSE AND CIRCUIT
BREAKER SIZE GUIDE
*For circuits not over 150 volts to ground.
LINE
LINE
GROUND
MOTOR
MOTOR