Chapter 3 Installing and Powering On the Sun Blade X6270 Server Module 35
Caution To protect electronic components from electrostatic damage, which can
permanently disable the system or require repair by Sun service technicians, place
components on an antistatic surface, such as an antistatic discharge mat, an antistatic
bag, or a disposable antistatic mat. Wear an antistatic grounding strap connected to
a metal surface on the chassis when you work on system components.
Install Server Module Into a Powered-On
Chassis
1. Verify that the Sun Blade 6000 or 6048 Series Chassis is powered-on.
When the chassis is powered-on, the fans are operating and the OK/Power LED
illuminates a
STEADY ON green light. The OK/Power LED is located on both the
front and rear panels of the chassis. If the chassis is not powered-on, refer to the
system chassis documentation.
2. In the front of the chassis, locate and remove the desired server module filler
panel.
Pull the lever out and eject the filler panel.
Caution If you are not installing a server module into a slot, do not remove the
server module filler panel from the slot. The server module filler panel is required to
meet FCC standards for electromagnetic interference (EMI).
3. Position the server module vertically so that the ejectors are on the right and
extend outward.
The following illustrations show the server module being inserted into the Sun
Blade 6000 Modular System; your chassis might differ. See box 1 in
FIGURE 3-1.