CGI Command Manual
101
11.26 Alarm out
Parameter Value InqParm SetCGI Ver Note
AlarmOut<AO>Func "on"/"off" alarmout<AO> alarmout.cgi 1.00
Ao<AO>Mode "alarm"/"timer"/"daynight" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmDetection "on"/"off" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmVmf "on"/"off" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmTampering "on"/"off" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmSensor<AI> "on"/"off" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmAud "on"/"off" alarmout<AO> alarmout.cgi 1.10
Ao<AO>AlmPeriod "always"/"schedule" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmSchedule "<schedule>" alarmout<AO> alarmout.cgi 1.00
Ao<AO>AlmDuration "1"to"60" alarmout<AO> alarmout.cgi 1.00
Ao<AO>TimSchedule "<schedule>" alarmout<AO> alarmout.cgi 1.00
Ao<AO>ManualFunc "on"/"off" alarmout<AO> alarmout.cgi 1.00
The command which can't be used in each model is shown in the following table.
Model name Unsupported commands (Alarm out)
SNC-CH120 Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-CH160 Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-CH220 Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-CH260 Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-DH120T Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-DH160 Ao<AO>AlmAud, Ao<AO>AlmVmf
SNC-DH220T Ao<AO>AlmAud, Ao<AO>AlmVmf