➃ At 65°F ambient and unit fired at full rated input. Max mounting height as measured from bottom of unit, and without deflector hoods.
➄ Note:Ratings shown are for elevations up to 2,000 feet.For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea
level. (In Canada see Rating Plate.) Reduction of ratings requires use of high altitude kit.
➅ Data listed is for standard 115-volt, 60-Hertz, single-phase motors. All single phase motors are totally enclosed and thermal overload protected.
A
H
D (OPENING)
BB
E
AA
B
K
W
X
F
C
CC
DD
J
L
(MIN. DISTANCE TO WALL)
➁
GAS SUPPLY
CONNECTION
2
7
/
8
"
FF
G
EE
3
3
/
8
"
3
1
/
8
"
4" ROUND FOR
PSH 130 thru 225
MODELS ONLY
COMBUSTION AIR
INLET COLLAR
(SIZES 280 & 340)
COMBUSTION AIR
INLET COLLAR
(SIZES 130-225)
3
1
/
8
"
4
1
/
2
"
OVAL COLLAR FITS
6" ROUND PIPE FOR
MODELS PSH 280 & 340 ONLY
K
The minimum recommended installation clearance from
top and rear of unit (motor) is six inches. Clearance to
sides is eighteen inches, and clearance at bottom should
equal “C” dimension shown in table for each model.
DO NOT USE PROPELLER UNITS WITH DUCT WORK.
Dimensions (in inches) — PSH
Performance—PSH
Dimension PSH 130 PSH 150 PSH 170 PSH 225 PSH 280 PSH 340
A
23-1/2 25-5/8 25-5/8 28-5/8 33-5/8 40
B
35-1/2 40-1/2 40-1/2 40-1/2 40-1/2 40-1/2
C
22 25 25 25 25 25
D
21-1/16 23-3/16 23-3/16 26-3/16 31-3/16 37-1/2
E
20 24 24 24 24 24
F
12-1/2 14-1/2 14-1/2 14-1/2 — —
G
1 2 2 2 1-5/8 1-5/8
H
19-7/8 22 22 25 30 36-3/8
AA
8 9 9 9 9 9
BB
7 1/2 7-1/2 7-1/2 7-1/2 7-1/2 7-1/2
CC
1 1/8 1/8 1/8 1-3/8 1-3/8
DD
3-1/4 3-1/4 3-1/4 3-1/4 3-5/8 3-5/8
EE
32-9/16 36 36 36 36-1/16 36-1/16
FF
6-1/2 6-1/2 6-1/2 6-1/2 5-7/8 5-7/8
J (Round)
4 4 4 4 6 6
K
➀ 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16 3/8-16
Natural Gas Connections
➂ 1/2 1/2 1/2 1/2 3/4 3/4
W
— — — — 5 5
X
— — — — 16 16
L
38-3/8 42 42 42 42 48
Fan Diameters
18 20 20 22 22 24
Approx. Ship. Wt.
198 244 246 272 328 422
➀ PSH 130 through PSH 225 — 2 holes.
PSH 280 & PSH 340 — 4 holes.
➁ Dimension from rear of unit burner box to center line of gas pipe connection is 6-23/32" for PSH 130 and 6-1/2" for all other models.
➂ For natural gas.
Btu/Hr Air Max. Mtg. Heat Standard Motor Data
➅
Input Btu/Hr CFM Outlet Temp. Height Throw
Model
➄
Output @ 70°F Velocity Rise (Ft.)
➃
(Ft.)
➃
HP Amps RPM Type
PSH 130
130,000 106,600 2540 940 39 12 50 1/6 2.8 1075 PSC
PSH 150
150,000 123,000 2900 810 39 16 50 1/6 2.8 1075 PSC
PSH 170
170,000 139,400 2900 820 45 16 50 1/6 2.8 1075 PSC
PSH 225
225,000 184,000 4275 1060 40 20 65 1/3 5.4 1075 PSC
PSH 280
280,000 229,600 4400 960 48 20 65 1/2 6.8 1075 PSC
P
SH 340
340,000 275,400 5300 980 48 20 65 1/2 6.8 1075 PSC
SEPARATED COMBUSTION PROPELLER UNIT HEATERS