3 - 80
3-3-3 Spindle specification parameters
The parameters with "(PR)" requires the CNC to be turned OFF after the settings. Turn the power OFF and
ON to enable the parameter settings.
【#3001】 slimt 1 Limit rotation speed (Gear: 00)
Set the spindle speed for maximum motor speed with gear 00.
(Set the spindle speed for the S analog output 10V.)
---Setting range---
0 to 99999 (r/min)
【#3002】 slimt 2 Limit rotation speed (Gear: 01)
Set the spindle speed for maximum motor speed with gear 01.
(Set the spindle speed for the S analog output 10V.)
---Setting range---
0 to 99999 (r/min)
【#3003】 slimt 3 Limit rotation speed (Gear: 10)
Set the spindle speed for maximum motor speed with gear 10.
(Set the spindle speed for the S analog output 10V.)
---Setting range---
0 to 99999 (r/min)
【#3004】 slimt 4 Limit rotation speed (Gear: 11)
Set the spindle speed for maximum motor speed with gear 11.
(Set the spindle speed for the S analog output 10V.)
---Setting range---
0 to 99999 (r/min)
【#3005】 smax 1 Maximum rotation speed (Gear: 00)
Set the maximum spindle speed with gear 00.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
【#3006】 smax 2 Maximum rotation speed (Gear: 01)
Set the maximum spindle speed with gear 01.
Set this as slimt >= smax.
By comparing the S command value and the values of gear 1 - 4, a spindle gear shift command will
be output automatically.
---Setting range---
0 to 99999 (r/min)
The configuration of the spindle specification parameters (#3001 to #3138) can differ depending on
the NC.
This Instruction Manual explains using the configuration of the parameters for M700V/M70V Series.