14.0 PARAMETER MENU
NOTE 1: Factory defaults are shown for a 60 Hz base frequency. See Parameter 48 for 50 Hz base frequency.
FACTORY
FACTORYFACTORY
FACTORY
NO.
NO.NO.
NO. PARAMETER NAME
PARAMETER NAMEPARAMETER NAME
PARAMETER NAME RANGE OF ADJUSTMENT
RANGE OF ADJUSTMENTRANGE OF ADJUSTMENT
RANGE OF ADJUSTMENT
DEFAULT
DEFAULTDEFAULT
DEFAULT
(NOTE 1)
01 LINE VOLTAGE HIGH (01), LOW (02) HIGH (01)
02 CARRIER FREQUENCY 4kHz (01), 6 kHz (02), 8 kHz (03), 10 kHz (04) 6 kHz (02)
03 START METHOD NORMAL (01), START ON POWER UP (02), NORMAL (01)
START WITH DC BRAKE (03),
AUTO RESTART WITH DC BRAKE (04),
FLYING RESTART 1 (05), FLYING RESTART 2 (06),
FLYING RESTART 3 (07)
04 STOP METHOD COAST (01), COAST WITH DC BRAKE (02), COAST (01)
RAMP (03), RAMP WITH DC BRAKE (04)
05 STANDARD SPEED KEYPAD (01), PRESET #1 (02), KEYPAD (01)
SOURCE SPEED POT (03)
06 TB-14 OUTPUT NONE (01), RUN (02), FAULT (03), NONE (01)
INVERSE FAULT (04), FAULT LOCKOUT (05),
AT SET SPEED (06), ABOVE PRESET #3 (07),
CURRENT LIMIT (08), AUTO SPEED (09),
REVERSE (10), DB BRAKE (11)
10 TB-13A FUNCTION NONE (01), SPEED POT (02), NONE (01)
SELECT PRESET SPEED #1 (03), START FORWARD (04),
RUN REVERSE (05), START REVERSE (06),
EXTERNAL FAULT (07), DB FAULT (08),
AUXILIARY STOP (09), ACCEL/DECEL #2 (10)
11 TB-13B FUNCTION NONE (01), SPEED POT (02), NONE (01)
SELECT PRESET SPEED #2 (03), DECREASE FREQ (04),
JOG FORWARD (05), JOG REVERSE (06),
EXTERNAL FAULT (07), DB FAULT (08),
AUXILIARY STOP (09), ACCEL/DECEL #2 (10)
12 TB-13C FUNCTION NONE (01), SPEED POT (02), NONE (01)
SELECT PRESET SPEED #3 (03), INCREASE FREQ (04),
START FORWARD (05), EXTERNAL FAULT (06),
DB FAULT (07), AUXILIARY STOP (08),
ACCEL/DECEL #2 (09)