A SERVICE OF

logo

TV measurement
32
TV measurement
Standard Change-Over
In TV mode, the MSK 25 can measure the following standards:
B/G standard
L standard
D/K standard
I standard
M/N standard
M1 standard (Japan)
Standard Change-Over TV Menu
[2ndF] [STD] Calling up standard change-over menu
[0] Addressing standard menu
[0] bis [6] Selecting standard
Example
Calling upB/G analogue standard:
Press [2ndF] [STD].
LC display:
1 = Analogue reception
2 = DVB-C reception
3 = DVB-T reception (if this option is provided)
0 = standard menu
Press [0].
The following menu is displayed:
1 = B/G standard- 2 = L standard - 3 = D/K standard etc.
Standard menu
Press [1]. The instrument is now set for analogue reception in the B/G
standard
Note
Please note that the selected standard will be retained after the
instrument has been switched off.
1=ANALOG 3=DVBT
2=DVBC 0=Std.
1=BG 2=L 3=DK
4=I 5=MN 6=M1
À