expAnded rAtinGS — GSC130481C*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
1400
MBh 40.8 42.3 46.3 - 39.9 41.3 45.3 - 38.9 40.3 44.2 - 38.0 39.3 43.1 - 36.1 37.4 41.0 - 33.4 34.6 37.9 -
S/T 0.68 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.78 0.66 0.45 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 2.46 2.52 2.62 - 2.69 2.75 2.86 - 2.88 2.96 3.07 - 3.06 3.14 3.26 - 3.21 3.29 3.41 - 3.34 3.42 3.55 -
Amps 9.9 10.1 10.4 - 10.6 10.9 11.2 - 11.5 11.7 12.1 - 12.2 12.5 12.9 - 13.0 13.3 13.7 - 13.7 14.0 14.5 -
HI PR 127 136 144 - 142 153 161 - 162 174 184 - 184 198 209 - 207 223 235 - 229 246 260 -
LO PR 60 63 69 - 63 67 73 - 66 70 76 - 69 73 80 - 72 77 84 - 75 79 87 -
1600
MBh 44.2 45.8 50.2 - 43.2 44.8 49.0 - 42.2 43.7 47.9 - 41.1 42.6 46.7 - 39.1 40.5 44.4 - 36.2 37.5 41.1 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
kW 2.53 2.60 2.69 - 2.76 2.83 2.94 - 2.97 3.04 3.16 - 3.15 3.23 3.35 - 3.30 3.39 3.52 - 3.44 3.52 3.66 -
Amps 10.1 10.4 10.7 - 10.9 11.1 11.5 - 11.8 12.1 12.4 - 12.6 12.9 13.3 - 13.3 13.6 14.1 - 14.1 14.4 14.9 -
HI PR 131 140 148 - 146 158 166 - 167 179 189 - 190 204 216 - 213 230 243 - 236 254 268 -
LO PR 62 65 71 - 65 69 75 - 68 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
1800
MBh 45.5 47.2 51.7 - 44.5 46.1 50.5 - 43.4 45.0 49.3
- 42.4 43.9 48.1 - 40.2 41.7 45.7 - 37.3 38.6 42.3 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
∆T 17 15 11 - 17 15 11 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
kW 2.56 2.62 2.72 - 2.79 2.86 2.97 - 3.00 3.07 3.19 - 3.18 3.26 3.38 - 3.34 3.42 3.55 - 3.47 3.56 3.69 -
Amps
10.2 10.4 10.8 - 11.0 11.2 11.6 - 11.9 12.2 12.6 - 12.7 13.0 13.4 - 13.4 13.8 14.2 - 14.2 14.6 15.0 -
HI PR 132 142 150 - 148 159 168 - 168 181 191 - 192 206 218 - 216 232 245 - 238 256 271 -
LO PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -
75
1400
MBh 41.5 42.7 46.2 49.6 40.5 41.7 45.2 48.5 39.6 40.7 44.1 47.3 38.6 39.7 43.0 46.2 36.7 37.8 40.9 43.9 34.0 35.0 37.9 40.6
S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39
∆T 21 19 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.48 2.55 2.64 2.74 2.71 2.78 2.88 2.99 2.91 2.99 3.10 3.22 3.09 3.17 3.29 3.41 3.24 3.32 3.45 3.58 3.37 3.46 3.59 3.72
Amps 10.0 10.2 10.5 10.9 10.7 11.0 11.3 11.7 11.6 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.1 13.4 13.8 14.3 13.8 14.2 14.6 15.2
HI PR 128 138 145 152 144 154 163 170 163 176 185 193 186 200 211 220 209 225 238 248 231 249 263 274
LO PR 60 64 70 75 64 68 74 79 66 70 77 82 70 74 81 86 73 78 85 90 75 80 88 93
1600
MBh 45.0 46.3 50.1 53.8 43.9 45.2 48.9 52.5 42.9 44.1 47.8 51.3 41.8 43.1 46.6 50.0 39.7 40.9 44.3 47.5 36.8 37.9 41.0 44.0
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
∆T 21 19 16 11 21 19 16 11
21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 2.56 2.62 2.72 2.82 2.79 2.86 2.97 3.08 3.00 3.07 3.19 3.31 3.18 3.26 3.39 3.52 3.34 3.42 3.55 3.69 3.47 3.56 3.69 3.84
Amps
10.2 10.4 10.8 11.1 11.0 11.2 11.6 12.0 11.9 12.2 12.6 13.0 12.7 13.0 13.4 13.9 13.4 13.8 14.2 14.7 14.2 14.6 15.0 15.6
HI PR 132 142 150 156 148 159 168 175 168 181 191 199 192 206 218 227 216 232 245 256 238 256 271 282
LO PR 62 66 72 77 66 70 76 81 68 73 79 84 72 76 83 89 75 80 87 93 78 83 90 96
1800
MBh 46.3 47.7 51.6 55.4 45.2 46.6 50.4 54.1 44.2 45.5 49.2 52.8 43.1 44.4 48.0 51.5 40.9 42.1 45.6 48.9 37.9 39.0 42.2 45.3
S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
∆T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 10 19 17 14 10
kW 2.58 2.65 2.75 2.85 2.82 2.89 3.00 3.11 3.03 3.10 3.22 3.34 3.21 3.29 3.42 3.55 3.37 3.45 3.58 3.72 3.50 3.59 3.73 3.87
Amps 10.3 10.5 10.9 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.3 14.9 14.3 14.7 15.2 15.7
HI PR 133 143 151 158 149 161 170 177 170 183 193 201 194 208 220 229 218 234 247 258 241 259 273 285
LO PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 90 76 81 88 94 78 83 91 97
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions