![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/e/e1/ee185ff2-a3c1-4fbd-9adb-5d010d23533a/ee185ff2-a3c1-4fbd-9adb-5d010d23533a-bg39.png)
Chapter 1 System Overview 1-25
The rack-mountable dual power feed option for the SPARC Enterprise M8000 server
receives power from two external AC power sources that are independent of each
other, and duplicates the input power system.
To use a single-phase dual power feed configuration for the SPARC Enterprise
M8000 server, mount the rack-mountable dual power feed option in the rack space
itself. This requires a rack space with a height of 6 RUs in the cabinet. For the SPARC
Enterprise M9000 server, you must add the power cabinet.
For three-phase power feed in either server, an additional power cabinet is required.
Install one power cabinet for each SPARC Enterprise M8000/M9000 Server.
For details, see the SPARC Enterprise M8000/M9000 Servers Site Planning Guide.
Note – A three-phase power feed option can be installed only at the factory before
shipment. A single-phase power feed cannot be changed to a three-phase power
feed, or vice versa, after shipment from the factory.
TABLE 1-7 lists specifications of the power cabinet.
TABLE 1-7 Specifications of the Power Cabinet and M8000/M9000 Dual Power Feed Option
Item
Rack-mountable Dual
Power Feed options
Power Cabinet
Outside dimensions Width [mm] 489
1003
278(6U)
75
317
Depth [mm] 1244
Height [mm] 1800
Weight [kg] 350
Input power:
Single-phase power
input
Voltage [V] AC200 to 240 ± 10%
Number of phases Single phase
Frequency [Hz] 50/60 +2%, -4%
Note – For specifications of the three-phase power feed option, see the SPARC