A SERVICE OF

logo

Confidential
EPSON
TITLE
SHEET
REVISION
NO
SHEETNEXT
91 92
A
TM-T81
Specification
(STANDARD)
<Function 067> GS ( k pL pH cn fn n (cn = 48 , fn = 67)
[Name] PDF417: Set the width of the module
[Format] ASCII GS ( k p
L pH cn fn n
Hex 1D 28 6B p
L pH cn fn n
Decimal 29 40 107 p
L pH cn fn n
[Range] (p
L + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 67
2 n 8
[Default] n = 3
[Description] Sets the width of the module for PDF417 to n dots.
<Function 068> GS ( k pL pH cn fn n (cn = 48 , fn = 68)
[Name] PDF417: Set the row height
[Format] ASCII GS ( k p
L pH cn fn n
Hex 1D 28 6B p
L pH cn fn n
Decimal 29 40 107 p
L pH cn fn n
[Range] (p
L + pH × 256) = 3 (pL = 3 , pH = 0)
cn = 48
fn = 68
2 n 8
[Default] n = 3
[Description] Sets the row height for PDF417 to [n × (the width of the module)].