![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/c8/6c80647d-e6d2-4086-b119-2ce8a0f221e8/6c80647d-e6d2-4086-b119-2ce8a0f221e8-bge4.png)
EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 228
FIP-70
Panel Message
D Open
Possible parts that caused the error
Troubleshooting
COVER-L DUP SWITCH-FUSER DOOR
HARNESS ASSY MAIN PWBA MCU
LV/HVPS
Step Check Yes No
1
Shape check of COVER-L DUP on Duplex
Is the actuator of the Duplex that presses
SWITCH-FUSER DOOR damaged?
Replace
COVER-L DUP.
(p.414)
Go to Step [2].
2
Operation check of SWITCH-FUSER DOOR
Disconnect the P/J403 from PWBA MCU.
Is there continuity on J403-11 ↔ J402-12
when the switch of SWITCH-FUSER DOOR
is pressed, and does the continuity stop when
the switch is released?
Go to Step [4]. Go to Step [3].
3
Continuity check of HARNESS ASSY MAIN
Disconnect the P/J403 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J403-11 ↔ J114-2
J403-12 ↔ J114-1
Replace
SWITCH-
FUSER DOOR.
(p.298)
Repair broken
or shorted part.
Actuator
4
Power supply check to PWBA MCU
Is the specified DC voltage being supplied to
the following terminals on PWBA MCU?
P410-1 ↔ P410-2: 3. 3 VDC
P410-3 ↔ P410-4: 5 VDC
P410-5/6 ↔ P410-7/8: 24 VDC
Replace PWBA
MCU. (p.404)
Go to Step [5].
5
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1 ↔ J502-1
J410-2 ↔ J502-2
J410-3 ↔ J502-3
J410-4 ↔ J502-4
J410-5 ↔ J502-5
J410-6 ↔ J502-6
J410-7 ↔ J502-7
J410-8 ↔ J502-8
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
Step Check Yes No