![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/34/d3433836-f60d-46bd-b5a0-beb9ef9a4e0c/d3433836-f60d-46bd-b5a0-beb9ef9a4e0c-bg48.png)
Stylus Photo R300/R310 Revision A
DISASSEMBLY AND ASSEMBLY Disassembly 72
External View
Figure 2-51. Removing "Ink System" (2)
9. Remove "Extension Spring, 0.441" from the hooks of "Slider, Cap" and
"Frame, Cap" by using the tweezers.
10. Remove "Extension Spring, 0.788" from the hooks of "Lever, Lock, Slider"
and "Frame, Cap" by using the tweezers.
11. Remove the shaft of "Slider, Cap" from the slot of "Frame, Cap", then remove
"Lever, Lock, Slider".
12. Remove "Porous, Slider, Cap" from the hook of "Slider, Cap".
Extension
Spring, 0.788
Extension
Spring, 0.441
Hooks
Frame, Cap
Slider, Cap
Shaft
Porous Pad, Slider, Cap
Hook
Lever, Lock, Slider
Reinstalling "Lever, Lock, Slider"
Check if it works properly working with "Slider, Cap".
Reinstalling "Ink System"
Make sure that the ink tube is correctly connected to the
point of "Frame, Cap" shown in the figure below. If it is not
connected properly, it may cause ink leakage.
Figure 2-52. Connecting Point for the ink tube
Do not touch the sealing rubber part and "Cleaner Head".
Make sure that the line mark of the ink tube is not twisted.
Check if "Cap Assy." moves smoothly.