The HBAnyware Utility User Manual Page 66
post-ip-buf Controller
Specific
128 64 1024 No This variable specifies the
number of 4K STREAMS
buffers to allocate and post to
the fibre channel IP ring.
Increase this setting for better
IP performance under heavy
loading.
scan-down Controller
Specific
1 0=Off 1=On Yes There are two scanning
algorithms used to discover a
node in a private loop. If scan-
down is 1, devices on
the private loop are scanned
starting from ALPA 0x01
through ALPA 0xEF. If scan-
down is 0, devices on
the private loop are scanned
starting from ALPA 0xEF
through ALPA 0x01. Scan-
down values 0 and 1 do
not apply if a loop map is
obtained. See the FC-AL
profile for the definition of a
loop map.
tgt-queue-depth Global 0 0 10240 No The driver uses this value as
the default limit for the number
of simultaneous commands to
issue to a single target on the
loop. A value of 0 causes no
target throttling to occur. A
single target will never be sent
more commands than allowed
by tgt-queue-depth; however,
less may be sent when sd-
max-throttle is reached for
the entire target.
Table 3: LPFC.conf Parameters (Continued)