5-3
Cisco SFS 7000P Hardware Installation Guide
OL-9167-01 Rev. A0
Chapter 5 Hardware Diagnostic Tests
Running Chassis Tests
Step 2 Exit the test to view the progress of the test.
The test takes approximately 5 to 8 minutes.
SFS-7000P# show diagnostic card 1
======================================================================
Diagnostic Tests For Cards
======================================================================
test : self-test
slot-id : 1
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Card Test Completed, Final report :
Passed=1, Failed=0, Total=1
Step 3 If the test fails, enter the more syslog:hwif_log command to see the log
information.
Running Chassis Tests
The following tests are available to locate and diagnose the chassis:
• LED
• Standard
• Extended
• Extended Memory
Running a Chassis Standard Test
The chassis standard test runs a diagnostic test on all cards in the chassis. To
perform a chassis standard test on a card, follow these steps:
Step 1 Start the test by entering the diag chassis test standard command and the start
command.