3-31
Cisco ONS 15530 Configuration Guide and Command Reference
78-16019-02, Cisco IOS Release 12.2(18)SV2
Chapter 3 Initial Configuration
Configuring Fan Failure Shutdown
Displaying the Fan Tray Failure Shutdown Configuration
To display the fan tray failure shutdown configuration, use the following EXEC command:
Example
The following example shows how to display the fan tray failure shutdown feature configuration:
Switch# show environment
Fan
---
Status: Total Failure
Line card shutdown on fan failure:enabled
Sensor Temperature Thresholds
(degree C) Minor Major Critcal Low
-------------------- ----------- ------------------------------------
Inlet Sensor 28 65 75 80 -15
Outlet Sensor 28 75 85 90 -15
Sensor Alarms
Min
Critical
-------------------- ------------------------
Inlet Sensor 0 0 0
Outlet Sensor 0 0 0
Power Entry Module 0 type DC status: OK
Command Purpose
show environment Displays the fan tray failure shutdown configuration.