![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/13/f13f3dbe-a20d-4202-aaed-fb539e908cdd/f13f3dbe-a20d-4202-aaed-fb539e908cdd-bg63.png)
Telephone: (508) 678-9000 Fax: (508) 678-9447
97
Relay Board Listing
TYPE
OF HEAT
ELECTRIC SERVICE
RELAY BOARD
PART NUMBER
VOLTAGE PHASE
WIRE
SERVICE
CONTROL VOLTAGE
120 VOLT 208/230 VOLT
GAS
Globar
®
Non-Hi/Lo 120 1ø 2 137077 or 137150 ---------
Globar
®
Non-Hi/Lo 208/230 1ø 2 --------- 137079
Globar
®
Non-Hi/Lo 208/480 3ø 3 --------- 137079
Globar
®
Hi/Lo 120 1ø 2 137077 or 137150 ---------
Globar
®
Hi/Lo 208/230 1ø 2 137077 ---------
Globar
®
Hi/Lo 208/480 3ø 3 137077 ---------
Direct Spark Ignition (DSI) 120 1ø 2 137076* ---------
Direct Spark Ignition (DSI) 208/230 1ø 2 --------- 137151
Direct Spark Ignition (DSI) 208/480 3ø 3 --------- 137078
ELECTRIC
15 Kw through 30 Kw
208/230 1ø 2 --------- 137151
208/480 3ø 3 --------- 137078*
208 3ø 4 137151 ---------
380/480 3ø 4 --------- 137078*
STEAM
Low Pressure 120 1ø 2 137151 ---------
Low Pressure 208/230 1ø 2 --------- 137151
Low Pressure 208/480 3ø 3 --------- 137078
High Pressure 120 1ø 2 137151 ---------
High Pressure 208/230 1ø 2 --------- 137151
High Pressure 208/480 3ø 3 --------- 137078
* May also use Part No. 137151 (Solid State Relay [SSR] Board).
IMPORTANT: Check label on relay board to verify correct part number.
NOTE: ADC Part No. 137151 (Solid State Relay [SSR] Board) cannot be used with 3-phase (3ø) motors.