Zenoah PE2300 Plumbing Product User Manual


 
PE2300
GB-12
12. Troubleshooting guide
Case 1. Starting failure
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel drain it and use correct fuel
fuel filter fuel filter is clogged clean
carburetor adjustment screw out of normal range adjust to normal range
sparking (no spark) spark plug is fouled/wet clean/dry
plug gap is incorrect correct (GAP: 0.6 to 0.7 mm)
spark plug disconnected retighten
Case 2. Engine starts but does not keep running/hard re-starting
CHECK PROBABLE CAUSES ACTION
fuel tank incorrect fuel or staled fuel drain it and use correct fuel
carburetor adjustment screw out of normal range adjust to normal range
muffler, cylinder (exhaust port) carbon is built-up wipe away
air cleaner clogged with dust wash
cylinder fin, fan cover clogged with dust clean
Case 3. No suction of water
CHECK PROBABLE CAUSES ACTION
self-suction port
insufficient self-sucking water in pump
top up with water(see Page 7)
hose, clump
loose connection of suction hose
tighten securely not to suck air
packing
faulty packing in suction hose connection
replace with proper one(ask for service)
hose
suction hose crack breakage
replace with proper one
hose, valve
folded discharge hose, closed valve
extend and stretch hose, open valve
Case 4. Discharge water flow rate too small
CHECK PROBABLE CAUSES ACTION
strainer clogged suction strainer cleaning of suction strainer
pump position
pump position too high from water level
lowering pump height to water level
water resource
too far or too high place to discharge
secure water resource near to discharge place
fuel engine output too low check fuel degrading, water ingress.
Replace if needed (see Page 7)
air filter check air filter clogging, cleaning
(see Page 9)
fuel filter check fuel filter clogging, cleaning
(see Page 9)
carburetor carburetor adjustment
suction side air invasion at suction side check piping at suction side
hose thin or long or kink of hose thicken or shorten or straighten
water resource
leak of water from water resource
stop leak
Case 5. Water leakage from pump
CHECK PROBABLE CAUSES ACTION
bolts Loosen assembly bolts Tightening of bolts
When your unit seems to need further service, please consult with our ZENOAH service shop in your area.