York THRU 060 Heat Pump User Manual


 
Unitary Products Group 9
66297-YIM-C-0205
TABLE 13 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HH036)
TABLE 12 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HH036)
INDOOR DB
TEMPERATURE,
°F
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
-100 102030405060
55 3.3 4.1 5.3 7.0 9.5 13.2
70 ————3.85.58.011.7
80 ——————4.58.2
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 5.2 7.3 9.4 11.6 13.7 15.8 20.0 24.2 28.4 32.6
70 6.4 8.2 10.0 11.8 13.6 17.9 22.2 26.5 30.8
75 5.5 6.9 8.4 9.8 11.3 15.7 20.2 24.6 29.1
80 5.7 6.8 7.9 9.1 13.6 18.2 22.7 27.3
85 ————5.26.06.811.516.2 20.8 25.5
90 ———————9.314.2 19.0 23.8
95 ———————7.212.1 17.1 22.0
100 ———————5.99.914.0 18.0
105 ————————7.710.9 14.0
110 ————————5.57.810.1
115 ——————————6.1
TABLE 10 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HH030)
TABLE 11 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HH030)
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 5.8 10.8 15.8 20.8 25.8 30.8 31.7 32.6 33.4 34.3
70 5.1 9.3 13.6 17.8 22.1 26.3 28.0 29.6 31.3 32.9
75 7.9 11.4 14.8 18.3 21.8 24.2 26.7 29.1 31.6
80 6.4 9.1 11.9 14.6 17.3 20.5 23.7 27.0 30.2
85 6.9 8.9 10.8 12.8 16.8 20.8 24.8 28.8
90 ————5.97.18.313.1 17.9 22.6 27.4
95 ———————9.414.9 20.5 26.0
100 ———————7.612.0 16.3 20.7
105 ———————5.99.012.2 15.3
110 ————————6.18.09.9
115 ———————————
INDOOR DB
TEMPERATURE,
°F
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
-100 102030405060
55 5.8 7.9 9.6 13.4 19.1 26.9 36.6
70 ————5.411.218.9 28.7
80 —————8.115.9 25.6