York TCHD18 THRU 60 Air Conditioner User Manual


 
556454-YTG-A-0210
6 Johnson Controls Unitary Products
— = Not applicable.
13 SEER AC WITH AHP / SHP / AHX / F*FP
TCHD18S41S3
AHX18 17 630 18.2 13.1 14.25 11.75
AHX24 17 590 18.3 13.0 14.25 11.75
AHX30 17 610 18.6 13.3 14.50 12.00
F6FP018 17 600 17.9 12.6 13.50 11.25
F6FP024 17 600 18.5 13.1 14.00 11.50
F6FP030 17 620 18.5 13.2 14.00 11.50
TCHD24S41S3
AHP24 17 850 23.0 16.8 13.15 11.05
AHX18 17 835 23.2 17.2 14.00 11.50
AHX24 17 800 23.6 17.3 14.00 12.75
AHX30 17 820 23.8 17.8 14.50 12.75
AHX36 21 815 24.2 18.1 15.00 12.25
F*FP030 17 800 23.0 16.7 13.10 11.00
F6FP024 17 840 23.4 17.4 14.00 11.50
F6FP030 17 850 23.4 17.4 13.75 11.25
F6FP036 21 855 23.8 17.9 14.25 11.75
TCHD30S41S3
AHP36 21 1000 28.4 21.2 13.75 12.20
AHX30 17 1025 28.4 21.3 14.50 12.50
AHX36 21 1005 29.0 21.7 15.25 13.25
AHX42 21 990 29.4 22.1 15.50 13.75
AHX48 24 1090 29.8 23.0 15.50 13.75
F*FP030 17 1000 27.6 20.0 13.20 11.85
F*FP036 21 1000 27.8 20.6 13.40 12.00
F*FP040 21 1000 27.8 20.4 13.40 12.00
F6FP030 17 1035 28.2 20.9 13.75 12.00
F6FP036 21 980 28.2 20.7 14.50 12.75
F6FP042 21 1065 29.6 22.4 15.25 13.50
F6FP048 24 1055 28.0 21.0 14.50 12.50
TCHD36S41S3
AHP36 21 1200 34.2 25.0 14.00 12.15
AHX36 21 1225 34.4 25.7 14.75 12.50
AHX42 21 1190 35.0 25.9 15.25 12.75
AHX48 24 1255 35.2 26.3 15.25 12.75
AHX60 24 1300 35.6 26.8 15.00 12.75
F*FP036 21 1200 33.0 23.8 13.00 11.35
F*FP040 21 1200 33.0 24.0 13.00 11.40
F*FP042 21 1200 33.0 24.0 13.00 11.40
F5FP048 24 1250 35.0 25.8 15.20 13.00
F6FP036 21 1210 33.4 24.3 13.75 11.75
F6FP042 21 1290 35.2 26.4 14.75 12.50
F6FP048 24 1125 32.2 23.3 14.00 11.75
F6FP060 24 1240 35.2 26.3 15.00 12.75
TCHD48S41S3
AHP/SHP60 24 1600 45.5 33.2 13.40 11.50
AHX48 24 1660 47.0 34.6 13.75 11.75
AHX60 24 1680 47.5 34.8 13.50 11.75
F5FP048 24 1700 47.5 35.0 13.75 12.00
F5FP060 24 1700 46.0 33.4 13.35 11.55
F6FP048 24 1625 45.0 33.2 13.00 11.00
F6FP060 24 1710 48.0 35.0 13.50 11.50
TCHD60S41S3
AHX60 24 1905 57.5 40.2 13.00 11.00
F6FP060 24 1710 56.5 38.7 13.00 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.