York R-410A Air Conditioner User Manual


 
251934-YTG-G-0708
48 Johnson Controls Unitary Products
115°F 125°F
6250
77 271.5 29.1 183.2 161.5 135.4 - - - 255.7 31.1 221.3 193.9 169.1 - - -
72 252.3 28.9 200.6 174.6 148.5 122.5 - - 237.6 31.1 217.0 192.2 167.4 142.5 - -
67 233.1 28.8 218.0 187.7 161.6 135.6 109.6 - 219.5 31.2 219.5 190.5 165.6 140.8 116.0 -
62 222.9 28.4 222.9 222.9 195.3 169.2 143.2 117.2 213.8 30.8 213.8 213.8 198.2 173.4 148.5 123.7
7500
77 286.4 29.1 207.0 178.3 149.6 - - - 267.2 31.0 244.2 212.4 184.7 - - -
72 266.2 29.0 221.4 192.8 164.1 135.4 - - 248.3 31.1 236.8 209.1 181.5 153.8 - -
67 246.0 28.9 235.9 207.2 178.6 149.9 121.2 - 229.3 31.2 229.3 205.9 178.2 150.6 122.9 -
62 235.2 28.5 235.2 235.2 215.7 187.1 158.4 129.7 223.5 30.8 223.5 223.5 213.1 185.4 157.8 130.1
57 233.5 28.8 233.5 233.5 213.3 184.7 156.0 127.3 222.0 31.4 222.0 222.0 208.2 180.5 152.9 125.2
8750
77 301.4 29.2 230.8 195.1 163.8 - - - 278.6 31.0 267.1 230.8 200.3 - - -
72 280.1 29.1 242.3 211.0 179.7 148.3 - - 258.9 31.1 256.5 226.0 195.6 165.1 - -
67 258.8 28.9 253.8 226.8 195.5 164.2 132.9 - 239.2 31.2 239.2 221.3 190.8 160.3 129.8 -
62 247.5 28.5 247.5 247.5 236.2 204.9 173.5 142.2 233.2 30.8 233.2 233.2 228.0 197.5 167.0 136.5
57 245.7 28.8 245.7 245.7 233.6 202.3 170.9 139.6 231.6 31.4 231.6 231.6 222.5 192.1 161.6 131.1
10000
77 316.4 29.3 254.6 212.0 178.0 - - - 290.1 31.0 290.1 249.2 215.9 - - -
72 294.0 29.1 263.1 229.2 195.2 161.3 - - 269.5 31.1 269.5 243.0 209.7 176.3 - -
67 271.7 29.0 271.7 246.4 212.4 178.5 144.5 - 249.0 31.1 249.0 236.7 203.4 170.1 136.8 -
62 259.7 28.6 259.7 259.7 256.6 222.7 188.7 154.8 242.9 30.8 242.9 242.9 242.9 209.6 176.3 142.9
57 257.9 28.9 257.9 257.9 253.8 219.8 185.9 151.9 241.2 31.3 241.2 241.2 236.9 203.6 170.3 137.0
11250
72 286.6 29.7 271.2 238.8 198.7 158.5 - - 261.6 32.0 261.6 252.8 212.7 172.7 - -
67 264.8 29.6 264.8 252.2 216.2 176.0 135.9 - 241.6 32.1 241.6 240.0 206.1 166.1 126.1 -
62 253.2 29.2 253.2 253.2 251.7 211.5 171.4 131.3 235.8 31.7 235.8 235.8 235.8 195.7 155.7 115.7
57 251.5 29.5 251.5 251.5 249.4 209.2 169.1 129.0 234.2 32.2 234.2 234.2 232.0 192.0 152.0 111.9
12500
72 279.3 30.3 279.3 248.4 202.1 155.8 - - 253.6 32.9 253.6 253.6 215.8 169.1 - -
67 258.0 30.1 258.0 258.0 219.9 173.6 127.3 - 234.3 33.0 234.3 234.3 208.9 162.1 115.4 -
62 246.7 29.7 246.7 246.7 246.7 200.4 154.1 107.7 228.7 32.6 228.7 228.7 228.7 181.9 135.2 88.4
57 245.0 30.0 245.0 245.0 245.0 198.7 152.3 106.0 227.1 33.1 227.1 227.1 227.1 180.4 133.6 86.9
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZF300 (25 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65