York PS8*DH Air Conditioner User Manual


 
279744-YTG-A-0407
Unitary Products Group 3
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
RATINGS & PHYSICAL / ELECTRICAL DATA
Models
Input Output
Nominal
Airflow
Cabinet
Width
Total Unit
Amps
AFUE
Air Temp.
Rise
MBH MBH CFM In. °F
PS8A12(N,L)040DH11 40 32 1200 14-1/2 9.0 80.0 20 - 50
PS8A12(N,L)060DH11 60 48 1200 14-1/2 9.0 80.0 25 - 55
PS8A12(N,L)080DH11 80 64 1200 14-1/2 9.0 80.0 35 - 65
PS8B16(N,L)080DH11 80 64 1600 17-1/2 12.0 80.0 25 - 55
PS8B12(N,L)100DH11 100 80 1200 17-1/2 12.0 80.0 40 - 70
PS8C16(N,L)100DH11 100 80 1600 21 12.0 80.0 25 - 55
PS8C20(N,L)100DH11 100 80 2000 21 14.0 80.0 25 - 55
PS8C16(N,L)115DH11 115 92 1600 21 12.0 80.0 35 - 65
PS8C20(N,L)115DH11 115 92 2000 21 14.0 80.0 30 - 60
PS8D20(N,L)130DH11 130 104 2000 24-1/2 14.0 80.0 40 - 70
Models
Input
Max. Outlet
Air Temp
Blower
Blower
Size
Max
Over-Current
Protect
Min. wire Size
(awg) @ 75 ft
one way
Operation
Weight
MBH °F Hp Amps In. Lbs.
PS8A12(N,L)040DH11 40 150 1/3 6.2 10 x 8 20 14 100
PS8A12(N,L)060DH11 60 155 1/3 6.2 10 x 8 20 14 110
PS8A12(N,L)080DH11 80 165 1/3 6.2 10 x 8 20 14 120
PS8B16(N,L)080DH11 80 160 3/4 11.0 11 x 10 20 14 130
PS8B12(N,L)100DH11 100 170 1/2 7.0 10 x 8 20 14 125
PS8C16(N,L)100DH11 100 155 3/4 11.0 11 X 10 20 14 140
PS8C20(N,L)100DH11 100 155 1 12.2 11 x 11 20 12 140
PS8C16(N,L)115DH11 115 165 3/4 11.0 11 x 10 20 14 150
PS8C20(N,L)115DH11 115 160 1 12.2 11 x 11 20 12 150
PS8D20(N,L)130DH11 130 170 1 12.2 11 x 11 20 12 160