York PAC036 Air Conditioner User Manual


 
036-21346-001 Rev. A (202)
Unitary Products Group 5
COOLING PERFORMANCE DATA
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
KW RATING IS FOR OUTDOOR UNIT ONLY.
Unit Model Number PAC036H1081A
INDOOR AIR
AMBIENT TEMPERATURE ENTERING CONDENSING COIL
85º 95º 105º 115º 125º
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
Indoor
CFM
Indoor
DB/WB
T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW
1000
85/71 37.6 24.5 3.91 35.2 22.4 4.14 32.3 21.1 4.34 29.3 19.7 4.53 26.4 18.4 4.73
80/67 35.3 23.6 3.87 33.1 23.2 4.10 29.0 20.8 4.25 24.9 18.5 4.41 20.8 16.2 4.57
75/63 32.4 22.4 3.80 30.3 21.2 4.03 26.3 19.1 4.14 22.2 17.0 4.25 18.1 14.9 4.36
1345
85/71 38.3 25.9 4.02 35.9 25.1 4.25 33.1 23.4 4.46 30.3 21.6 4.66 25.0 20.1 4.86
80/67 36.2 25.0 3.89 32.6 24.1 4.05 30.1 22.2 4.29 25.8 21.7 4.50 19.8 19.0 4.50
75/63 33.4 23.8 3.82 29.6 23.1 3.98 27.1 20.4 4.17 22.1 20.1 4.36 16.9 16.0 4.42
1400
85/71 39.3 27.4 4.12 37.0 26.4 4.35 34.2 25.0 4.57 31.3 23.5 4.79 28.5 22.1 5.01
80/67 37.2 26.1 4.05 35.0 24.5 4.28 31.3 23.4 4.46 27.5 22.2 4.64 23.7 21.0 4.82
75/63 34.5 25.1 3.98 32.5 22.8 4.20 27.9 21.7 4.34 23.3 20.7 4.47 18.7 19.7 4.60
Unit Model Number PAC048H1081A
INDOOR AIR
AMBIENT TEMPERATURE ENTERING CONDENSING COIL
85º 95º 105º 115º 125º
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
Indoor
CFM
Indoor
DB/WB
T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW
1300
85/71 51.6 31.8 5.44 48.7 30.5 5.79 45.9 29.1 6.13 43.0 27.8 6.47 40.2 26.5 6.81
80/67 48.3 30.9 5.38 45.1 29.3 5.69 41.9 27.6 6.00 38.7 26.0 6.31 35.5 24.4 6.62
75/63 44.7 30.1 5.26 40.9 28.1 5.54 37.0 26.1 5.81 33.2 24.1 6.08 29.4 22.1 6.35
1500
85/71 52.6 33.3 5.56 49.9 32.0 5.92 47.2 30.8 6.27 44.5 29.5 6.63 41.7 28.2 6.99
80/67 49.1 32.5 5.50 47.1 31.4 5.82 43.0 29.6 6.14 36.6 28.2 6.47 31.1 27.1 6.79
75/63 45.6 31.7 5.38 42.3 30.8 5.66 38.1 27.9 5.94 32.4 25.8 6.22 26.0 24.6 6.50
1700
85/71 53.6 34.8 5.68 51.1 33.6 6.05 48.5 32.4 6.42 45.9 31.2 6.79 43.3 30.0 7.16
80/67 49.9 34.1 5.62 47.0 32.9 5.95 44.0 31.6 6.29 41.1 30.3 6.62 38.2 29.0 6.96
75/63 46.4 33.3 5.51 42.8 31.5 5.79 39.1 29.7 6.08 35.4 27.9 6.36 31.7 26.1 6.65
Unit Model Number PAC060H1081A
INDOOR AIR
AMBIENT TEMPERATURE ENTERING CONDENSING COIL
85º 95º 105º 115º 125º
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
CAPACITY
MBTUH
Indoor
CFM
Indoor
DB/WB
T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW T.C. S.C. KW
1500
85/71 59.6 37.4 6.25 55.8 35.5 6.62 51.9 33.7 6.98 48.0 31.8 7.35 44.1 30.0 7.72
80/67 55.5 36.5 6.13 51.2 34.3 6.49 46.9 32.2 6.84 42.6 30.0 7.19 38.3 27.9 7.54
75/63 50.4 34.9 6.02 46.2 32.7 6.36 41.9 30.4 6.69 37.6 28.1 7.03 33.3 25.8 7.37
1560
85/71 60.3 38.6 6.32 56.5 36.9 6.70 52.6 35.1 7.07 48.8 33.3 7.44 44.9 31.5 7.81
80/67 56.0 37.8 6.21 55.9 37.0 6.56 47.4 33.5 6.91 47.2 33.1 7.27 40.6 31.1 7.62
75/63 53.3 36.3 6.10 52.7 35.9 6.44 42.6 31.6 6.78 42.0 31.4 7.12 33.5 25.9 7.46
1700
85/71 61.0 39.9 6.40 57.2 38.2 6.78 53.3 36.5 7.15 49.5 34.8 7.53 45.7 33.1 7.91
80/67 56.4 39.1 6.28 52.2 37.0 6.64 47.9 34.8 6.99 43.6 32.6 7.34 39.3 30.4 7.69
75/63 52.2 37.8 6.18 47.7 35.3 6.53 43.3 32.9 6.87 38.8 30.4 7.21 34.4 28.0 7.55