York MLCA-MLHA-07-24 Air Conditioner User Manual


 
6
ENGLISH
OPTIMAL OPERATION
To achieve optimal performance, Please note the following:
Adjust the air flow direction correctly so that it is not directed on people.
Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.
Close doors and windows on COOL or HEAT modes, or performance may be reduced.
Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air
conditioner may stop running.
Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
Do not operate unit with horizontal louver in closed position.
PREPARATION BEFORE INSTALLATION
Before doing any work, check the interior power supply cord and the main breaker capacity are sufficient and the
installation area is sufficient and complies with the requirements.
Check that the power supply available agrees with name plate voltage.
Electrical work, wiring and cables must be in compliance with national and local wiring codes and standard.
Do not use the extension cables. In the case extended cables are needed, use the terminal block.
SELECTION OF THE LOCATION
Select a place which provides the space around the units as shown in the diagram below.
INDOOR UNIT OUTDOOR UNIT
Do not install in a place that cannot bear the weight of the unit.
CAUTION
Models
07 09 12 18 24
A 12cm 12cm 12cm 12cm 12cm
B 70cm 70cm 70cm 70cm 70cm
C 12cm 12cm 12cm 12cm 12cm
D 15cm 15cm 15cm 15cm 15cm
Models
07 09 12 18 24
A 30cm 30cm 30cm 30cm 30cm
B 200cm 200cm 200cm 200cm 200cm
C 60cm 60cm 60cm 60cm 60cm
D 30cm 30cm 30cm 30cm 30cm