York E*FH060 Air Conditioner User Manual


 
036-21031-004 Rev. A (0603)
Unitary Products Group 21
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO E4FH042S06
EVAPORATOR COIL MODEL NO F2RP/F2FP042
AIR TEMP.
ENTERING
OUTDOOR
UNIT
AIR TEMP.
ENTERING
INDOOR
COIL
ID CFM
1200 1400 1000
MBTUH K.W. C.O.P. MBTUH K.W. C.O.P. MBTUH K.W. C.O.P.
60
60 49.03.713.9448.53.633.9247.23.563.90
70 50.23.973.7750.03.893.7849.13.813.79
80 50.14.333.4550.24.243.4949.74.143.53
47
60 42.43.353.7241.93.313.7141.33.273.70
70 42.83.593.5042.03.733.3042.13.503.53
80 42.43.913.1842.33.853.2242.13.803.25
40
60 38.53.433.2738.13.403.2637.73.373.26
70 38.33.683.0338.13.643.0437.93.613.05
80 37.43.992.7337.43.952.7637.33.902.79
30
60 33.13.292.9233.13.292.9233.13.282.93
70 32.53.542.6632.53.522.6832.43.502.69
80 31.53.842.3831.43.802.4031.33.752.42
17
60 26.3 3.08 2.51 26.6 3.09 2.53 26.9 3.11 2.55
70 25.13.272.2525.23.362.2025.83.292.30
80 23.83.521.9924.33.522.0224.73.532.05
10
60 22.43.072.1922.83.102.1923.13.132.20
70 20.93.241.9221.33.271.9421.73.311.96
80 19.43.461.6820.03.491.7120.53.521.74
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
F2FP048 1.00 0.92 1.08
G2FD042(S,H)21 0.99 0.96 1.03
G2FD046(S,H)17 0.99 0.96 1.03
G2FD048(S,H)21,24 1.00 0.92 1.08