York CZH024 THRU 060 Air Conditioner User Manual


 
350154-YTG-B-0408
Johnson Controls Unitary Products 13
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
NOTE: KW RATING IS FOR OUTDOOR AND INDOOR UNITS.
LOW CFM
COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
OUTDOOR UNIT MODEL NO. CZH04811
INDOOR COIL MODEL NO. FC62D + MV20D
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM 950 1000 1050
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 35.4 36.6 36.2 39.8 42.3 36.1 37.2 36.8 40.2 42.9 36.8 37.8 37.4 40.6 43.4
S.C. 34.3 31.8 26.9 27.2 21.7 34.8 32.5 27.6 27.8 22.0 35.3 33.3 28.2 28.5 22.3
K.W. 1.50 1.50 1.49 1.48 1.48 1.50 1.49 1.49 1.48 1.47 1.49 1.49 1.49 1.47 1.47
75
T.C. 34.0 34.9 34.5 37.8 40.4 34.6 35.4 35.0 38.2 40.9 35.2 36.0 35.5 38.6 41.5
S.C. 32.9 31.0 26.2 26.4 21.0 33.4 31.7 26.8 27.0 21.3 33.9 32.4 27.4 27.6 21.7
K.W. 1.81 1.81 1.81 1.80 1.79 1.81 1.81 1.80 1.79 1.78 1.80 1.80 1.80 1.79 1.78
85
T.C. 32.5 33.1 32.8 35.7 38.5 33.1 33.7 33.2 36.2 39.0 33.7 34.2 33.6 36.6 39.5
S.C. 31.5 30.2 25.5 25.5 20.3 32.0 30.9 26.0 26.1 20.7 32.5 31.6 26.6 26.7 21.1
K.W. 2.12 2.12 2.12 2.11 2.10 2.12 2.12 2.12 2.11 2.10 2.12 2.12 2.11 2.11 2.09
95
T.C. 31.1 31.4 31.1 33.7 36.6 31.7 31.9 31.4 34.2 37.1 32.2 32.4 31.7 34.6 37.6
S.C. 30.1 29.4 24.8 24.7 19.6 30.6 30.1 25.3 25.3 20.0 31.1 30.8 25.8 25.8 20.4
K.W. 2.44 2.44 2.44 2.43 2.41 2.43 2.43 2.43 2.43 2.41 2.43 2.43 2.43 2.42 2.40
105
T.C. 29.4 29.7 28.9 31.5 34.2 30.0 30.2 29.3 31.9 34.6 30.5 30.7 29.6 32.3 35.0
S.C. 28.5 27.8 23.8 23.8 18.7 28.9 28.5 24.3 24.4 19.1 29.4 29.1 24.8 24.9 19.6
K.W. 2.86 2.87 2.87 2.87 2.84 2.86 2.86 2.86 2.86 2.84 2.86 2.86 2.86 2.85 2.84
115
T.C. 27.8 28.0 26.9 29.3 31.9 28.4 28.6 27.2 29.7 32.2 28.9 29.1 27.6 30.1 32.5
S.C. 26.9 26.3 22.9 23.0 17.8 27.4 26.9 23.4 23.5 18.3 27.8 27.5 23.9 24.1 18.7
K.W. 3.28 3.28 3.29 3.29 3.26 3.27 3.28 3.28 3.27 3.26 3.27 3.27 3.28 3.27 3.26
125
T.C. 26.2 26.4 24.8 27.1 29.6 26.7 26.9 25.2 27.5 29.8 27.2 27.5 25.6 27.9 30.0
S.C. 25.4 24.8 21.9 22.1 16.9 25.8 25.4 22.4 22.7 17.4 26.2 26.0 22.9 23.3 17.9
K.W. 3.69 3.70 3.71 3.71 3.67 3.69 3.69 3.70 3.69 3.67 3.69 3.69 3.70 3.68 3.68
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
AV/SV48D 0.97 0.97 1.00
AV/SV60D 0.97 0.97 1.00
F4FV060 0.99 0.98 1.01
MV16C FC/MC/PC48C 1.00 1.00 0.99
MV16C FC/MC/PC48D 1.00 1.00 0.99
MV16C UC48D 1.00 1.00 0.99
MV20D FC/MC/PC48D 1.00 1.00 1.00
MV20D UC48D 1.00 1.00 1.00
MV20D FC/MC62D 1.00 1.00 1.00
Variable Speed
Furnace
Coil
T.C. S.C. KW
PV8*C16 FC/MC/PC48C 0.97 0.97 0.98
PV8*C16 FC/MC/PC48D 0.97 0.97 0.98
PV8*C16 UC48D 0.97 0.97 0.98
PV8*C20 FC/MC/PC48C 1.00 1.00 0.99
PV8*C20 FC/MC/PC48D 1.00 1.00 0.99
PV8*C20 UC48D 1.00 1.00 0.99
P(C,V)9*C16 FC/MC/PC48C 1.01 1.02 0.98
P(C,V)9*C16 FC/MC/PC48D 1.01 1.02 0.98
P(C,V)9*C16 UC48D 1.01 1.02 0.98
P(C,V)9*C20 FC/MC/PC48C 0.99 0.99 1.00
P(C,V)9*C20 FC/MC/PC48D 0.99 0.99 1.00
P(C,V)9*C20 UC48D 0.99 0.99 1.00
P(C,V)9*D20 FC/MC/PC48D 0.99 0.99 1.00
P(C,V)9*D20 UC48D 0.99 0.99 1.00
PV8*C20 FC/MC62D 1.00 1.00 0.99
P(C,V)9*C20 FC/MC62D 1.00 1.00 1.00
P(C,V)9*D20 FC/MC62D 0.99 0.99 1.00
P(C,V)9*D20 HC60D 0.95 0.95 1.00