York BQ 036 Heat Pump User Manual


 
036-21508-005-A-0305
Unitary Products Group 17
TABLE 4: BQ048 COOLING CAPACITIES (4 TON)
CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68
72 56 4.1 42 36 31 26 - - - 53 4.5 40 35 29 24 - - -
67 53 4.0 48 47 41 36 30 25 - 51 4.4 46 45 41 35 30 24 -
62 49 4.0 49 49 48 44 38 33 28 46 4.3 46 46 45 41 35 30 24
57 49 3.9 49 49 49 44 38 33 28 46 4.3 46 46 46 41 35 30 24
72 55 4.0 40 35 30 25 - - - 53 4.4 38 33 28 23 - - -
67 52 4.0 47 44 39 34 29 24 - 51 4.4 44 44 39 34 29 24 -
62 48 3.9 48 48 47 43 38 33 28 47 4.3 47 47 45 40 36 31 26
57 48 3.9 48 48 48 43 38 33 28 45 4.2 45 45 45 40 35 30 25
72 53 4.0 37 33 28 24 - - - 52 4.4 36 32 27 23 - - -
67 51 4.0 46 42 37 33 28 24 - 50 4.3 44 43 38 34 29 25 -
62 47 3.9 47 47 46 41 37 32 28 45 4.2 45 45 44 40 36 31 27
57 47 3.9 47 47 47 42 38 33 29 44 4.1 44 44 44 40 36 31 27
72 52 4.0 34 30 26 22 - - - 49 4.3 33 29 25 21 - - -
67 49 3.9 42 38 34 30 26 22 - 47 4.2 42 38 34 30 26 22 -
62 46 3.8 46 45 42 38 34 30 26 43 4.1 43 42 40 36 32 28 24
57 45 3.8 45 45 43 39 35 31 27 42 4.1 42 42 40 36 32 28 24
72 50 3.9 31 27 24 20 - - - 47 4.2 29 25 22 18 - - -
67 47 3.9 38 35 31 28 24 21 - 45 4.2 37 34 30 27 23 20 -
62 44 3.8 44 42 39 35 32 28 25 40 4.1 40 39 36 32 29 25 22
57 44 3.7 44 43 39 36 32 29 25 40 4.0 40 39 36 32 29 25 22
CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68
72 51 4.9 40 35 29 24 - - - 49 5.2 39 34 29 23 - - -
67 46 4.7 42 42 39 34 28 23 - 41 5.0 40 40 37 32 26 21 -
62 43 4.6 43 43 42 37 32 27 21 40 4.9 40 40 39 34 29 23 18
57 43 4.6 43 43 43 38 32 28 22 40 4.8 40 40 40 34 30 24 19
72 50 4.8 38 33 28 23 - - - 47 5.1 37 32 27 22 - - -
67 45 4.7 41 41 37 32 27 22 - 40 4.9 37 36 35 30 25 20 -
62 42 4.6 42 42 41 37 32 27 22 39 4.8 39 39 37 34 29 24 19
57 42 4.5 42 42 42 37 33 27 23 38 4.7 38 38 38 33 30 25 20
72 49 4.8 35 31 26 22 - - - 46 5.1 34 29 25 20 - - -
67 44 4.6 40 40 35 31 26 22 - 39 4.9 36 36 32 28 23 19 -
62 41 4.5 41 41 40 35 32 27 23 37 4.7 37 37 36 33 28 24 19
57 41 4.4 41 41 41 36 32 28 23 37 4.7 37 37 37 34 28 25 20
72 47 4.7 32 28 24 20 - - - 44 5.0 31 27 23 19 - - -
67 42 4.5 38 36 32 28 24 20 - 37 4.8 36 34 30 26 21 17 -
62 39 4.4 39 38 37 33 28 25 20 36 4.7 36 35 34 30 26 22 18
57 39 4.4 39 39 37 33 29 25 21 36 4.6 36 36 34 31 26 23 19
72 44 4.6 28 25 21 18 - - - 42 4.9 28 24 21 17 - - -
67 40 4.5 36 32 29 25 22 18 - 36 4.7 34 31 27 24 20 17 -
62 38 4.4 38 36 34 29 27 22 20 35 4.6 35 34 30 28 24 20 17
57 37 4.3 37 37 34 30 27 23 20 35 4.6 35 35 31 29 24 21 18
NOMINAL RATING
1200
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
TOTAL
CAP.
1
MBH
POWER
INPUT
2
kW
TOTAL
CAP.
1
MBH
2000
1800
1600
1400
POWER
INPUT
2
kW
ENTERING DRY BULB, °F ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
105°F 115°F
SENSIBLE CAPACITY
1
SENSIBLE CAPACITY
1
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
AIR ON
EVAPORATOR
COIL
TEMPERATURE OF AIR ON CONDENSER COIL
1200
1400
85°F
POWER
INPUT
2
kW
95°F
SENSIBLE CAPACITY
1
ENTERING DRY BULB, °F
2000
1800
1600
1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower motor from the SUPPLY AIR BLOWER PERFORMANCE
Table, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input
is 0.35kW. Refer to the SUPPLY AIR BLOWER PERFORMANCE Table for the kW of the supply air blower motor.