TABLE 16: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY W/O PWRD CONVENIENCE OUTLET
TABLE 17: ELECTRICAL DATA DH120 (10 TON) HIGH EFFICIENCY WITH PWRD CONVENIENCE OUTLET
RL
A
LR
A
FL
A
23 2 3 23232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
2TP04525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34 81.8 112.5 115.9 119.4 122.7 125 125 125 125
2TP04525425 129.9 140.2 143.5 147.0 150.4 150 175 175 175
None -- -- 26 27.2 28.2 29.4 30 35 35 35
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
2TP04525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
2TP04525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70
*
Pwr
Exh
Motor
Electric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 4.1 5.3 2.2 0.0
3.5 8.2 10.916.0 137.0
8.3 69.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
6.4 58.0 1.3 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
Outlet
Heater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208
16.0 137.0 3.5
230
460
575
Voltage
Compressors
OD Fan
Motors
Supply
Blower
Motor FLA
54
RL
A
LR
A
FL
A
23 2 3 23232 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
2TP04525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34 81.8 125.0 128.4 131.9 135.2 125 150 150 150
2TP04525425 129.9 152.7 156.0 159.5 162.9 175 175 175 175
None -- -- 31 32.2 33.2 34.4 35 40 40 40
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
2TP04525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
2TP04525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70
*
2.2 5.0
6.4 58.0 1.3 3.6 4.1 1.8 4.0
8.3
3.5 8.2 10.9 5.5 10.0
3.5 8.2 10.9 5.5 10.0
69.0 1.6 4.1 5.3
460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
Compressors
OD Fan
Motors
16.0 137.0
16.0 137.0
Voltage
Electric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
54