Yeoman YM-CL3MF Stove User Manual


 
5
USER INSTRUCTIONS
Airwash Control
CLOSE OPEN
Primary Control
CLOSE OPEN
PR8721 PR8722
DOOR OPERATION
1.14 Use a protected gloved hand to operate.
DO NOT OPEN THE DOOR WITH BARE HANDS
To Open and Close
Rotate handle and pull door to open
PR8723 PR8724
WARNING
Properly installed, operated and maintained this
appliance will not emit fumes into the room.
Occasional fumes from de-ashing and refuelling may occur.
Persistent fume emission is potentially dangerous and
must not be tolerated.
If fume emission does persist:
Open doors and windows to ventilate the room.
Allow fire to burn out and safely dispose of fuel from the
appliance.
Check for chimney blockage and clean if required.
Do not attempt to relight until the cause of the emission
has been identified and corrected.
If necessary seek expert advice.
All open flued appliances can be affected by temporary
atmospheric conditions which may allow fumes to
enter the house. Because of this an electronic carbon
monoxide detector conforming to the latest edition
of BSEN50291 must be fitted in the same room as
the appliance. The existence of an alarm must not be
considered a substitute for ensuring regular servicing
and maintenance of the appliance and chimney system.
If the alarm sounds follow the instructions given under
Warning above.
2. USING THE APPLIANCE FOR THE FIRST
TIME
2.1 To allow the appliance to settle, and fixing glues and paint
to fully cure, operate the appliance at a low temperature for
the first few days.
2.2 Do not touch the paint during the first period of use.
2.3 During this time the appliance may give off some
unpleasant odours. Keep the room well ventilated to avoid
a build-up of fumes.
2.4 Please be aware that, during use, rope seals may discolour.
This is normal.
3. RECOMMENDED FUELS
3.1 Wood Logs
Burn only seasoned timber with a moisture content of less
than 20%. To ensure this allow cut wood to dry for 12 to
18 months.
Wood Length
Appliance Wood Length
CL3 200mm
CL5 330mm
CL8 400mm
Poor quality timber:
Causes low combustion efficiency.
Produces harmful condensation.
Reduces effectiveness of the airwash and life of the
appliance.