27
Length (mm)
Seal Yeoman
CL3
Yeoman
CL5
Yeoman
CL8
Door rope seal C 1400 1600 2300
Door rope seal D 175 175 410
Mid door rope seal E
(CL8 models only)
n/a n/a 450
—Remove the old rope.
—Scrape old glue from the locating groove.
—Clean the locating groove with a clean dry cloth
removing all dust and debris.
—Apply Stovax Thermic Seal glue (Stovax Part No. 5037)
into the rope locating groove.
—Press the new rope into the locating groove,
placing the joint in the middle of the lower edge of the
door.
—Refit the door.
—Close to apply pressure on the new rope.
6.2 Leave the appliance closed for at least 12 hours before
lighting the stove.
6.3 Use at a low temperature for approximately one day.
Using the stove with a damaged door seal could allow
dangerous fumes to enter the room, or the appliance to
over-fire and cause damage.
—Clean, and re-paint, the rear of the door if required.
—Clean the screws with light oil.
—Coat with high temperature anti-seize grease to aid
future removal.
—Carefully wrap glass sealing rope (A) round the sides and
bottom edge of the glass.
—Fix glass sealing rope (B) to the matt black side of the
top face as shown in diagram above.
—Place the glass into position in the door.
—Place the glass clamp into position.
—Re-fix with the clean fixing screws.
—Tighten the screws evenly until the clamp holds the
glass.
Do not over tighten the clamp as this could break the
glass.
5.2 Fit only Yeoman ceramic glass, which is suitable to use in
high temperature applications.
5.3 Using the appliance with damaged door glass could allow
dangerous fumes to enter the room, or the appliance to
over-fire and cause damage.
6. FITTING A NEW DOOR SEAL
6.1 To maintain the safe use of your appliance you may need
to replace a damaged or worn door sealing rope. To do
this:
—Open the door.
—Lift it free of the hinge blocks.
—Lie the door face down on a soft flat surface, to protect
the paintwork and glass.
PR8758
Joint
Mid door
rope seal E
(CL8 models
only)
Door rope seal D
Door rope seal C
MAINTENANCE and SERVICING