9. EXTENDED BURNING
9.1 It is possible to get the appliance to burn for extended
periods. In order to do this:
De-ash prior to final refuelling.
Set air controls to low combustion settings. This will
blacken the glass over night but it will clear when
operated at high output for a short period.
Use smokeless fuel or small, thick logs depending on fuel
desired.
10. OVER-FIRING
10.1 Do not over-fill with fuel or use at maximum output for
long periods or over-firing can occur. If the flue pipe, flue
collar or top plate glow red the appliance is over-firing.
Close the air controls to reduce the output.
10.2 Over-firing can cause permanent damage to the appliance.
11. CHIMNEY FIRE
11.1 If a chimney fire occurs:
Shut all air controls immediately.
Evacuate the building.
Call the fire brigade.
Do not re-enter the building until it is confirmed safe.
11.2 Do not use the appliance after a chimney fire until:
a) It has been inspected by a registered installer,
confirming the appliance is safe to use*.
b) The chimney system inspected and swept by a chimney
sweep, confirming the system is structurally sound and
free from obstruction before re-use**.
c) It is repaired as required before re-use. Use only
genuine Stovax replacement parts to keep your appliance
in safe and efficient working order.
USER INSTRUCTIONS
11
PR8883
Place flat on the fixings on the bottom of the appliance
(see Diagram 12).
12
PR8884
Fit the plug supplied in the right hand side where the
riddling mechanism is located (see Diagram 13).
13
PR8454
Plug
Clamp
Bolt
Replace the log bar.
11
* Registered on the Competent Persons Scheme (UK only)
see page 14 / INFO (Republic of Ireland).
**This should be done by a HETAS Approved Chimney
Sweep (UK only) see page 14 / INFO registered (Republic
of Ireland only) who will issue you with a certificate.