A SERVICE OF

logo

11
Because each installation is unique to the property, it is
not possible to give full details to suit every setting.
However the installation should comply with the
requirements of the Building Regulations and be made
using ‘best practice’ construction methods.
Remember that many fireplace openings will have a
supporting lintel. Do not remove this without making
provision to support the remaining structure of the
building.
The Elegance stove must not form any part of
the supporting structure.
1.1 Remove all packing and temporary transportation fixings
from the Elegance stove, check that no parts have been
left in the ashpan.
1.2 Lift the stove into position on the prepared hearth area,
taking care not to damage the hearth finish.
1.3 To connect 6: (150mm) flue pipe (Stovax part 4602) to
the stove in accordance with Building Regulations
(Document J) an adapter (Stovax part YM-EL200ADPT)
must be fitted between the flue pipe and the stove.
1.4 Seal the connecting joints with fire cement.
1.5 Top flue pipe installation
1.6 Connect a flue pipe by inserting it into the flue spigot
and sealing using fire cement.
1.7 Typical top flue installation. Flue to be installed in
accordance with manufacture’s instructions.
1.8 As it is not possible to fully sweep the flue through the
stove, provision must be made to clean the flue and
collect debris without removing the stove.
Seal Collar with Fire Cement
Size Stovax Part No
5” 4502
6” 4602
Size Stovax Part No
5 4502
6” 4602
Size Stovax Part No
5 4512
6” 4612
To chimney connection as
detailed in building regulations
600mm
minimum
1000mm
maximum
un-supported