Yeoman 200 Stove User Manual


 
PRE-INSTALLATION CHECKS
10
1
.12 Where a hearth, fireplace, flue or chimney is provided or
e
xtended (including cases where a flue is provided as part
of refurbishment work), information essential to the
correct appliance and use of these should be permanently
posted in the building, to meet Requirement J4 of the
Building Regulations (England and Wales), F3.12
(Scotland).
2. ADDITIONAL VENTILATION
2.1 Additional ventilation will be required to comply with
the requirements of the Building Regulations. This
should be provided using a permanently open air vent, of
the size listed, which is positioned so that it is not liable
to be blocked both inside and outside the building.
2.2 Extractor fans or cooker hoods should not be placed in
the same room or space as the appliance.
2.3 If any of these checks reveal problems, do not proceed
with the fitting of the appliance until they have been
rectified.
Model
Elegance 200
Elegance 210
Elegance 220
Elegance 240
Elegance 250
Elegance 270
Elegance 280
Additional Ventilation
mm
none none 1100 none 550 550 1650
cm
- - 11 - 5.5 5.5 16.5
sq. inch
- - 4.33 - 2.17 2.17 6.50