Xpelair CF20T Fan User Manual


 
Tilbehør
For å forenkle installasjonen og
spare tid, kan det være at din
installasjon krever noe av
tilbehøret som er listet opp
nedenfor:
WD100 Vegg-gjennomføring
CFWG100 Vegg-gitter
FDA Utstyrspakke med
plant kanaladapter
XCT100 Kondensavskiller
DGW/B Gitterluke for
luftutskiftning
SP100 Muffeplate
XAA Luftadapter for mur
VC10 Avtrekksdeksel
WT10 Kanalavslutnings-sett
XF/FM Plan rørkanal
(plast/metall)
(plast 234 x 29 mm
metall 230 x 25 mm)
VK10 Veggventil-sett
FD100 Fleksibel rørkanal
WDC5 Snekkeskrue-klips
XCMK Sett for montering i
himling
XBP In-line
tilbakeslippsklaff
EFT Lettmontert
avslutnings-sett
GMK Sett for montering i
vindu
PDXGF Fettfilter
Nedenfor er det listet opp enkelte
reservedeler som er tilgjengelige.
Se baksiden på denne trykksaken
for bestillingsinformasjon:
41520SK Monterings-sett
(komplett)
41528SK Rund muffe (komplett)
41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/
DX200T)
41782SK Kretskort-komponent
(DX200T)
41735SK Kretskort-komponent
(CF20)
41736SK Kretskort-komponent
(CF20T)
41737SK Frontdeksel kompl.
med mottrykksplate
(DX200)
41738SK
Frontdeksel kompl. med
mottrykksplate (DX200T)
41739SK
Frontdeksel kompl. med
mottrykksplate
(CF20/CF20T)
41740SK Innfatningsprofil
(komplett)
41741SK
Snorbryter-komponent
(CF20/CF20T)
41742SK Viftehjul (komplett)
Tillbehör
I listan nedan hittar du hjälpmedel
som kan vara av nytta under
installationen:
WD100 Väggtrumma
CFWG100 Väggaller
FDA Adaptorsats för
planmontering
XCT100 Kondensavledare
DGW/B Luftregleringsgaller
SP100 Mufförbindningsplatta
XAA Adapter
VC10 Ventilhuv
WT10 Avspänningssats
XF/FM Planmontering
(plast/metall)
(plast 234 x 29 mm)
(metall 230 x 25 mm)
VK10 Väggventilsats
FD100 Flexibel
ledningsdragning
WDC5 Skruvdriftsklämmor
XCMK Takmonteringssats
XBP Svart reglerventil
EFT Avspänningssats
GMK Glasmonteringssats
PDXGF Smörjningsfilter
I listan nedan hittar du
reservdelar. Du hittar
beställningsinformation på denna
bruksanvisnings baksida:
41520SK Fastsättningssats
(komplett)
41528SK Mufförbindning
(komplett sortiment)
41731SK Motor (DX200)
41733SK Motor (CF20/CF20T/
DX200T)
41782SK PCB-montering
(DX200T)
41735SK PCB-montering
(CF20)
41736SK PCB-montering
(CF20T)
41737SK Främre skydd med
skärm (DX200)
41738SK Främre skydd med
skärm (DX200T)
41739SK
Främre skydd med
skärm (CF20/CF20T)
41740SK Ramformning
(komplett sortiment)
41741SK Dragsnöresmontering
(CF20/CF20T)
41742SK Fläkthjul (komplett
sortiment)
Accessori opzionali
Per un’installazione più facile e
veloce, potrebbero essere
necessari alcuni degli accessori
sottoelencati:
WD100 Condotto per parete
CFWG100 Grata per parete
FDA Kit adattatore per
condotto piatto
XCT100
Pozzetto di
intercettazione della
condensa
DGW/B Grata dello sportello di
ricambio aria
SP100 Piastra di imbocco
XAA Adattatore per mattoni
traforati
VC10 Cappottatura di
ventilazione
WT10 Kit di terminazione
condotti
XF/FM Condotti piatti
(plastica/metallo)
(plastica 234 x 29mm,
metallo 230 x 25mm)
VK10 Kit di ventilazione per
parete
FD100 Condotti flessibili
WDC5 Fermagli a vite senza
fine
XCMK Kit di montaggio al
soffitto
XBP Otturatore in linea del
tiraggio di ritorno
EFT Kit di terminazione di
facile montaggio
GMK Kit per il montaggio su
vetro
PDXGF Filtro antigrasso
Qui di seguito sono elencati alcuni
dei ricambi disponibili. Per
informazioni su come ordinarli,
consultare la quarta di copertina:
41520SK Kit di fissaggio (kit
intero)
41528SK Imbocco a bicchiere
circolare (intera
gamma)
41731SK Motorino (DX200)
41733SK Motorino (CF20/
CF20T/DX200T)
41782SK Gruppo PCB
(DX200T)
41735SK Gruppo PCB (CF20)
41736SK Gruppo PCB (CF20T)
41737SK Coperchio anteriore
completo di
diaframma (DX200)
41738SK Coperchio anteriore
completo di
diaframma (DX200T)
41739SK Coperchio anteriore
completo di
diaframma
(CF20/CF20T)
41740SK
Modanatura della
cornice
(intera gamma)
41741SK
Gruppo cordicella
(CF20/CF20T)
41742SK
Girante (intera
gamma)
Συµπληρωµατικές Επιλγές
Γι α γρήγρη και εύκλη
εγκατάσταση, η εγκατάσταση
σας µπρεί να ρειαστεί µερικά
απ τα Συµπληρωµατικά πυ
αναέρνται πι κάτω:
WD100 Αγωγς τίυ
CFWG100 Κιγκλίδωµα τίυ
FDA Πρσαρµγέας
επίπεδυ αγωγύ
XCT100 Ατµπαγίδα
DGW/B Κιγκλίδωµα πρτας
ανανέωσης αέρα
SP100 Πλάκα ύσµατς
XAA Πρσαρµγέας
τύλυ αέρα
VC10
Κάλυµµα αεραγωγύ
WT10 Σύνλ αγωγύ
τερµατισµύ
XF/FM Επίπεδς αγωγς
(πλαστικ/µέταλλ)
(Πλαστικ 234  29 λστ.
Μέταλλ 230  25 λστ.)
VK10 Σύνλ αεραγωγύ
τίυ
FD100 Εύκαµπτς αγωγς
WDC5 Κλιπ ιειδύς
κίνησης
XCMK
Σύνλ τπθέτησης
σε ταάνι
XBP Φράτης
πισθδρµικύ
ρεύµατς in-line
EFT Σύνλ
τερµατισµύ
εύκλης εαρµγής
GMK
Σύνλ τπθέτησης
γυαλιύ
PDXGF Φίλτρ γράσυ
Πι κάτω αναέρνται µερικά
απ τα διαθέσιµα ανταλλακτικά.
Συµυλευθείτε την πίσω ψη
τυ παρντς υλλαδίυ για
λεπτµέρειες παραγγελίας:
41520SK Σύνλ στερέωσης
(λκληρ σύνλ)
41528SK Κυκλικ ύσµα
41731SK Μτέρ (DX200)
41733SK
Μτέρ (CF20/CF20T/
DX200T)
41782SK
Σύνλ PCB (DX200T)
41735SK Σύνλ PCB (CF20)
41736SK
Σύνλ PCB (CF20T)
41737SK
Μπρστιν κάλυµµα
συνδευµεν απ
εκτρπέα (DX200)
41738SK Μπρστιν
κάλυµµα
συνδευµεν απ
εκτρπέα (DX200T)
41739SK
Μπρστιν κάλυµµα
συνδευµεν απ
εκτρπέα (CF20/CF20T)
41740SK υτ πλαίσι
(λκληρη σειρά)
41741SK Σύνλ κρδνιύ
τραήγµατς
(CF20/CF20T)
41742SK Στρεί
(λκληρη σειρά)
N S I GR
For speed and ease of Installation, your installation may require some of the
Ancillaries indicated in “Ancillary Options”.
If installing on a wall (surface mounting)
1. Mark on the wall the centre of the duct hole A.
2. Use this centre to cut an opening through the wall 117mm dia, with a slight
fall to the exterior.
3. Fit the wall duct (WD100), not supplied, and mortar into place.
If installing on a wall (flush mounting)
1. Mark on the wall the centre of the duct hole A, and drill a pilot
hole through both walls at a slight downward angle.
2. Use the centre to mark a rectangular hole for the inner wall using the
dimensions
A.
3. Cut the rectangular hole through the inner wall.
4. Go outside and cut a 117mm-diameter hole in the outer wall using the small
hole as the centre.
5. Measure the wall thickness.
Cut the wall duct (WD100), not supplied, so that it is 64mm less than the
wall thickness.
If installing in a ceiling (surface mounting)
This method requires a space above the ceiling, such as a loft or attic, to provide
access for 100mm internal diameter ducting.
1. Mark on the ceiling the centre of the duct hole A, avoiding ceiling joists and
buried cables etc.
2. Cut a 117mm-diameter hole using the marked centre.
If installing in a ceiling (flush mounting)
For 100mm diameter ducting:
1. Mark a rectangular hole using the dimensions
B.
2. Cut the hole, avoiding ceiling joists and buried cables etc.
For flat ducting:
This fan can be installed within a 47mm void without the circular spigot
7
(Fig.E). Flat ducting adapter kit (FDA) available.
Preparing the fan for installation
1. Remove the front cover 2 (Fig.C)
2. Fit the foam tape
!™ supplied around the circular spigot 7 (Fig.E).
3. Remove the electrical cover
5 (Fig.E). The impeller can be removed to
ease access (if required). This is a "push-on/pull-off" assembly.
Setting the fan speed
DX200T / CF20 / CF20T Only (Fig.D)
4. The correct condensation control speed (CF20/CF20T) or operating speed
(DX200T) should be selected to suit the room size in which the fan is to be
installed. Slide the switch
X to the required position. Please note that the
fan is factory set to “Position 2”.
5. Switch Position Size / Room Volume (m
3
)
1 Large (34 and above)
2 Medium (28 – 34)
3 Small (less than 28)
Setting the trickle speed
DX200T / CF20 / CF20T Only (Fig.D)
6. The fan can be set so that it provides constant trickle extraction. Slide the
switch
Y to the required position. Please note that the fan is factory set to
“Position 0”.
7. Switch Position Setting
0Trickle extraction OFF
ITrickle extraction ON
Setting the time delay start
DX200T / CF20T Only (Fig.D)
8. The fan can be set so that there is a 2-minute delayed start to its
operation when used with an external on/off switch. Slide the
switch
Z to the required position. Please note that the fan is
factory set to “Position 0”.
Switch Position Setting
0Time delay start OFF
ITime delay start ON
Mounting the fan on a wall or ceiling (surface mounting)
1. Place the ducting into the hole and align to the required position. If wall
mounting, ensure that the ducting slopes down and away from the fan
2. Mark the positions of the three fixing holes
A in Fan box 6 (Fig.E).
3. If wall mounting, drill three holes 5.5mm diameter for wall plugs (supplied).
If ceiling mounting
B , use appropriate fasteners (not supplied).
4. Cut out the cable inlet hole, if required, in the surround
0 and slit the cable
grommet. Slide the surround
0 over the fan box 6.
5. Pass the electrical cables into the fan box
6 through the rear cable inlet
hole and surround, and re-fit the cable grommet.
Ensure that cable grommet is in place and a tight fit.
6. Offer the fan box 6 up to the wall or ceiling. Ensure the circular spigot 7
enters the ducting.
7. Fix the fan box
6 to the wall using screws 8 or to the ceiling using
appropriate fasteners (not supplied).
If mounting in a wall (flush mounting)
The surround 0 is not required. Fit the ducting to the circular spigot 7.
If the hole size is as recommended:
1. Assemble the three fan body clamps 9 to the fan box 6 using screws 8.
2. Slit the cable grommet. Pass the electrical cables into the fan box
6
through the cable inlet hole and cable grommet.
Ensure cable grommet is in place and a tight fit.
3. Offer the fan box 6 up to the wall.
4. Tighten up the three screws
8 until the fan is clamped to the inner wall.
The fan body clamps
9 will rotate to an automatic stop position. DO NOT
OVERTIGHTEN
.
If the hole size is larger than recommended i.e.: larger than the flange on the
fan box
66
(Mostly relating to “retro-fit” installations):
1. The fan body clamps ARE NOT suitable. Construct a wooden frame of
INTERNAL dimensions 203 x 233mm. Depth should be at least 50mm. Fit the
1. READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION.
2. INSTALLATIONS AND WIRING MUST CONFORM TO CURRENT IEE REGULATIONS (UK), LOCAL OR APPROPRIATE
REGULATIONS (OTHER COUNTRIES). IT IS THE INSTALLER’S RESPONSIBILITY TO ENSURE THAT THE APPROPRIATE
BUILDING CODES OF PRACTICE ARE ADHERED TO.
3. A QUALIFIED ELECTRICIAN MUST SUPERVISE ALL INSTALLATIONS.
4. THESE APPLIANCES ARE INTENDED FOR CONNECTION TO FIXED WIRING
5. CHECK THAT THE ELECTRICAL RATING SHOWN ON THE FAN MATCHES THE MAINS SUPPLY.
6.
WARNING: THESE APPLIANCES MUST BE EARTHED.
7. SITE AWAY FROM DIRECT SOURCES OF HEAT (I.E.: GAS COOKERS OR EYE-LEVEL GRILLS) AND NOT WHERE
AMBIENT TEMPERATURES ARE LIKELY TO EXCEED 50˚C.
8. WHEN THE FAN IS INSTALLED IN A ROOM CONTAINING A FUEL BURNING APPLIANCE, PRECAUTIONS MUST BE TAKEN TO
AVOID THE BACKFLOW OF GASES INTO THE ROOM FROM THE OPEN FLUE OF THE FUEL BURNING APPLIANCE.
9. ENSURE THAT ALL RELEVANT SAFETY PRECAUTIONS (CORRECT EYE PROTECTION AND PROTECTIVE CLOTHING
ETC) ARE TAKEN WHEN INSTALLING AND MAINTAINING THIS FAN.
10. GENERAL GUIDANCE FOR SITING THE FAN SEE “FIG. G”. ALWAYS SITE FAN AS HIGH AS POSSIBLE
11. IF ANY SECTION OF THE DUCTWORK IS POSITIONED HIGHER THAN THE FAN A CONDENSATION TRAP (XCT100) MUST
BE FITTED AS CLOSE AS POSSIBLE TO THE FAN.
GB
IMPORTANT