MACHINE OPERATION
86037580 GLIDE 01/03/07
3-16
EMPTYING AND CLEANING TANKS
RECOVERY TANK
1. Touch the one-touch switch (#1) on the control
panel to raise the scrub deck, stop the motors,
and solution flow, raise the squeegee and turn
off vacuum motors.
2. Park the machine next to a floor drain. Drain
hose is on left rear corner of machine.
3. Turn off the key switch and set the machine’s
parking brake.
4. Unhook the drain hose from retainer. Unscrew
T-handle on plug enough to loosen plug and
lower hose in direction of drain. Stand behind
end of hose. Recovered solution will come out
with force. Slowly remove plug from drain hose.
5. Remove recovery tank dome.
6. Flush the recovery tank out with clean water.
Repeat until clean water comes out of drain
hose. Do not use water hotter than 140' (60'C)
to clean the tank. Damage to tank may occur.
7. Replace plug and secure drain hose in bracket.
8. If machine is to be stored, leave recovery tank
dome open and drain hose plug off.
SOLUTION TANK
1. Park the machine next to a floor drain. Drain
hose is on left rear adjacent to recovery tank
drain hose.
2. Turn off the key switch and set the machine’s
parking brake.
3. Unhook the small drain hose from the retainer.
Lower hose in direction of the drain.
4. Remove the solution tank cover.
5. Flush the solution tank out with clean water and
run several gallons of clean water through
systems. Do not use water hotter than 140º F
(60º C) to clean tank. Damage may occur.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.
6. Secure drain hose in bracket.
REAR VIEW
TOP VIEW
RECOVERY
DRAIN HOSE
SOLUTION
DRAIN HOSE
RECOVERY
TANK DOME
SOLUTION
TANK COVER