GROUNDING INSTRUCTIONS
D100 86038260 05/21/07
2-
3
THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
In the USA this machine operates on a standard
15 amp 115V, 60 hz, A.C. power circuit . The
amp, hertz, and voltage are listed on the data
label found on each machine. Using voltages
above or below those indicated on the data label
will cause serious damage to the motors.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should
malfunction or break down, grounding provides a
path of least resistance for electric current to
reduce the risk of electric shock. This appliance
is equipped with a cord having an equipment-
grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet
that is properly installed and grounded in
accordance with all local codes and ordinances.
This appliance is for use on a nominal 115-volt
circuit, and has a grounded plug that
looks like the plug in “Fig. A”. A temporary
adaptor that looks like the adaptor in “Fig . C”
may be used to connect this plug to a 2-pole
receptacle as shown in “Fig. B”, if a properly
grounded outlet is not available. The temporary
adaptor should be used only until a properly
grounded outlet (Fig. A) can be installed by a
qualified electrician. The green colored rigid ear,
lug, or the like extending from the adaptor must
be connected to a permanent ground such as a
properly grounded outlet box cover. Whenever
the adaptor is used, it must be held in place by a
metal screw.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualified electrician or service
person if you are in doubt as to whether the
outlet is properly grounded. Do not modify the
plug provided with the appliance - if it will not fit
the outlet, have a proper outlet installed by a
qualified electrician.
Using the incompatible chemicals listed above
will damage the machine. Damages of this
type are not covered under the warranty.
Carefully read ingredients on manufacturer's
label before using any product in this machine.
NOTE: In Canada, the use of a temporary adaptor is no
t
p
ermitted by the Canadian Electrical Code
PROPER GROUNDING
Metal Screw
A
daptor
Grounded Outlet Box
Fig. A
Fig. B
Fig. C
Tab For Grounding Screw
Grounded
Outlet
Grounding Pin
A
dapto
r
CHEMICALS
Suitable Chemicals
A
lkalis
Detergents
Hydroxides
Soaps
Vinegar
Non-Compatible
A
ldehydes
A
romatics Hydrocarbons
SP Butyls
Carbon Tetrachloride
Clorox*
Chlorinated Bleaches
Chlorinated Hydrocarbons
Lysol*
Methyl Ethel Ketone (MEK)
Perchorethylene (perc)
Phenolics
Trichlorethylene
D-Limonene