Windsor 10061160 Vacuum Cleaner User Manual


 
MACHINE OPERATION
86317500 CHARIOT SCRUBBER 11/15/08
3-16
TO STOP SCRUBBING
1. Rotate the function knob to either transport
position. The brush motors will stop and the
scrub deck will rise to the park position. After 10
seconds the squeegee will raise, and 10
seconds later the vacuum motor will turn off.
This delay is to clear the vacuum hose of
recovered solution.
2. Allow the throttle pedal to return to neutral.
3. Turn machine power off.
FOR SAFETY: Before leaving or servicing
machine: stop on level surface, turn off machine
and remove key.
DOUBLE SCRUB
For floors which are heavily soiled or have thick
accumulations of floor finish, may not clean
sufficiently with one pass. In these cases it will be
necessary to double scrub.
Rotate the knob to the double scrub position labeled
“C”, make the first pass over the surface being
cleaned with the squeegee up, vacuum off and the
solution on. For best results also remove the Aqua-
mizer™, this will allow the solution to stay in contact
with the soil while loosening the surface
accumulation with the brushes. Allow time for the
first application to stay in contact with the floor.
Length of time between the first and second pass
depends on amount of accumulation and the type of
chemical being used. A second scrubbing with the
function knob in one of the normal scrubbing modes
will lower the squeegee and will keep the solution on
and brushes down to further loosen soil. The
additional application of solution will further assist
the difficult cleaning job.
FOR SAFETY: When using machine, go slow on
inclines and slippery services.