Williams 4003532 Gas Heater User Manual


 
2
201842
DIRECT-VENT NATURAL GAS HEATER
THE COMFORT PRODUCTS PEOPLE
gases will result. Carbon monoxide
poisoning from backed-up flue gases
could occur. The State of California
lists carbon monoxide as a reproduc-
tive toxin under Proposition 65.
7. Never install the furnace
in a recreational vehicle
in an alcove
on an inside wall
as a fireplace insert
in high traffic areas
in windy or drafty areas
behind a door or where an open door
would block normal air flow
8. Provide the following minimum fur-
nace clearances from furnace front
cover to combustibles (as viewed from
the front of furnace):
Below Front Cover: 6 inches
Adjoining Wall: 12 inches
Above Front Cover: 12 inches
Front: 8 feet
9. Do not obstruct the flow of combus-
tion and ventilation air in any way. Pro-
vide adequate clearances around air
openings into the combustion chamber
along with adequate accessibility clear-
ance for servicing and proper operation.
10. Provide the following minimum furnace
clearances from furnace cabinet (portion
of cabinet extending into outside air, as
viewed from the rear of furnace):
Cabinet Back: 36 inches
Cabinet Sides: 6 inches
Cabinet Bottom: Must be high enough
off the ground to prevent snow, water,
leaves, or any other objects from block-
ing cabinet vents.
11. Always follow lighting instructions.
Never attempt to light burner with a
match or butane torch.
12. Do not run furnace
where flammable liquids or vapors
are used or stored
under dusty conditions
13. Do not use furnace as a cooking device.
14. Do not alter furnace or its controls. Any
change may create a safety hazard.
15. Do not use furnace if any part has been
under water. Immediately call a quali-
fied service person to inspect the fur-
nace and to replace any part of the con-
trol system and any gas control which
has been under water.
Carbon Monoxide Poisoning: Early signs of
carbon monoxide poisoning resemble the flu,
with headaches, dizziness, and/or nausea. If
you have these signs, the furnace may not be
working properly. Get fresh air at once! Have
furnace serviced. Some people are more af-
fected by carbon monoxide than others. These
include pregnant women, people with heart or
lung disease or anemia, those under the influ-
ence of alcohol, and those at high altitudes.
Natural Gas: Natural gas is odorless. An odor-
making agent is added to natural gas. The odor
helps you detect a natural gas leak. However,
the odor added to natural gas can fade. Natural
gas may be present even though no odor exists.
Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your
guide to safe and proper operation of this furnace.
1. A qualified service person must install
furnace.
2. This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases.
3. Use only natural gas. Do not convert
furnace to use different fuel type.
4. If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
5. Do not block the flow of combustion
air (outside air) or heated air (room air)
to the furnace.
6. This furnace must have fresh air for
proper operation. If not, poor fuel com-
bustion and improper venting of flue
SAFETY
INFORMATION
WARNINGS
IMPORTANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate,
or service this furnace. Improper
use of this furnace can cause seri-
ous injury or death from burns, fire,
explosion, electrical shock, and
carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
WARNING: Any change to
this heater or its controls can
be dangerous.
Do not place clothing or other
flammable material on or near
the appliance. Never place any
objects on the furnace.
Surface of furnace becomes very
hot when running furnace. Keep
children and adults away from
hot surface to avoid burns or
clothing ignition. Furnace will re-
main hot for a time after shut-
down. Allow surface to cool be-
fore touching.
Due to high temperatures, the
appliance should be located out
of traffic and away from furniture
and draperies.
Carefully supervise young chil-
dren when they are in the same
room with furnace.
Turn off furnace and unplug and let
cool before servicing. Unless you
need gas supply for testing, shut
off equipment shutoff valve before
servicing. Only a qualified service
person should service and repair
furnace and venting system.
Replace any safety screen or
guard removed for servicing be-
fore operating furnace.
You must keep control compart-
ments, burners, and circulating
air passages clean. More frequent
cleaning may be needed due to
excessive lint and dust from car-
peting, bedding material, etc.
Turn off the gas valve and unplug
before cleaning furnace.