V. CONTINUOUS DRAINAGE
1. This appliance can be configured to avoid periodical-
ly manually emptying the water bucket. You can use the
supplied drain hose to connect to the continuous drain-
age connector.
2. Unscrew and remove the drain cover at the rear of
the appliance.
3. Remove the soft rubber stopper. Put it into the water
bucket for safe keeping.
4. Insert the drain hose through the hole of the drain
cover.
5. Connect the drain hose to the drain port.
6. Tighten the drain cover in clockwise direction on to
the rear of the appliance.
7. Place the bucket on its original location.
INSTALLING DRAINAGE HOSE
When using the function of continuous drainage, the hose must be placed horizontally below the drainage
hole. Avoid uneven ground and folding the hose.
GRAVITY METHOD
This dehumidifier comes standard with a 3 ft. drain hose. To use gravity to drain your portable dehumidifier, it
must be installed on a level surface or at least 12 inches above the ground, on a sturdy table or shelf unit.
When using the function of continuous drainage, the hose must be placed horizontally below the drainage
hole. Avoid uneven ground and folding the hose.
NOTE: When using continuous drainage setup, there may be some water collected in the water in the
drain bucket