TW2000 WOOD-FIRED BOILER – INSTRUCTION MANUAL
TW2000 10/6/05
2
SECTION 1 – OPERATING INSTRUCTIONS
KERR TW2000 Wood-Fired Boiler
Tested by: Warnock Hersey Professional Services Ltd. to CSA standard B366.1
Certified by the Canadian Standards Association (CSA) May 1984
COSP. WWP-009
Manufactured by: Parrsboro Metal Fabricators Ltd.
P.O. Box 637, Crossroads
12118 Highway 209
Parrsboro Nova Scotia, Canada
B0M 1S0
Specifications
Cabinet Length 36”
Width 22”
Height 36”
Shipping Weight 600 lb.
Fire Box Length 36”
Width 16”
Height 26”
Water Volume US Gallons 26.10
IMP. Gallons 21.73
Liters 98.80
Heat Exchanger 3/16” & 12-gauge steel
Fire Box Door Cast Iron 13” x 13”
Supply 1 ¼”
Return 1 ¼”
Smoke Pipe 7” Inside Diameter
Smoke pipe exit Top
Output (max): 70,000 Btu/h
Fuel: Wood 30” logs maximum
Boiler Water Volume 26.0 U.S. gal.
Domestic Hot Water Coil Optional
Electrical Rating: Volts 120, 15Amps
NOTE – Keep this manual in a safe place for future reference. Follow manual
carefully for the correct way to install and operate this unit.
CAUTION – Do not fire this unit until operating instructions have been read and
fully understood.
INSTALL WOOD-FIRED BOILER ONLY ON A FLUE SYSTEM AND CHIMNEY
THAT ARE IN GOOD CONDITION.
SAVE THESE INSTRUCTIONS