White Rodgers 90 Thermostat User Manual


 
14
compressor failure by “locking out”
the compressor. This ensures that the
compressor will stay off for at least
five minutes on each cycle. When the
thermostat is in compressor lock-out,
the word COOL will flash. During this
period, the compressor will not be
energized
Programmable Fan Control.
This feature allows you to have your
fan operate continuously through one
or more programmed time periods.
This is useful if you want to have
constant air circulation during a
specific time period. If you do not use
this feature, the fan will cycle normally
with the heating and cooling system.
To program the fan, follow the steps in
the PROGRAMMING section. In each
time period, you can press the FAN
key to select a continuous fan or a
normally cycling fan. The display will
show PRG FAN ON when continuous
fan is selected. This means at the time
you set the period to start, the fan will
come on and run until the next
program time period
Example: Your thermostat is pro-
grammed with the original factory
settings for the Monday OCCU period
in the heating mode.
Pressing PROGRAM
VIEW
will
display OCCU, 8AM, 70 and PRG
FAN ON. Pressing the FAN key will
toggle the programmable fan off and a
second press would turn it back on.
When PRG FAN ON is in the upper
right of the display, your thermostat is
programmed to adjust the temperature
to 70° at 8AM and also bring the fan
on to run constantly until the next
program time period.
At the next time period you may
choose to continue the program fan
feature. Change to the next program
period and press the FAN key until
PRG FAN ON is on the display. The
fan will continue to run through this
period as well as the previous one.
If the thermostat is in a period with
continuous fan and you want the fan to
cycle, press the FAN key. PRG FAN
ON on the display will turn off.
Air Filter Change-Out Indicator.
This feature allows the thermostat to
display CHNG FLTR (change filter)
after a set time of fan operation. This is
a reminder to change or clean your air
filter. The factory set interval for
CHNG FLTR to be displayed is 200
hours of fan operation. This can be set
anywhere from 0 to 1950 hours in 25
hour increments. A selection of 00 will
cancel this feature.
When CHNG FLTR is displayed, you
can clear it by pressing the FILTER
key. This resets the timer and starts
counting the hours until the next filter
change.