White Rodgers 24A07A-1 Thermostat User Manual


 
3
WIRING CONT.
In operation, a circuit is completed through the bimetal
heater as the low voltage room thermostat closes its
contacts. In approximately 45 seconds, the warping ac-
tion of the heater closes the line voltage snap-switch to
energize the heating load. When the thermostat opens
its contacts, the bimetal heater cools for approximately
45 seconds before the line voltage switch opens to de-
energize the heating load.
All wiring should be done in accordance with local and national electrical codes and ordinances.
USING ONE THERMOSTAT AND TWO OR MORE SILENT OPERATORS TO “SEQUENCE” LOADS
Figure 5 shows how several Silent Operator relays can be
used to “sequence on” separate heating loads. The red
and white leads of additional Silent Operator relays should
be jumpered as shown. All wiring should be performed
exactly as shown.
As the thermostat closes its contacts, each separate heat-
ing load will be “sequenced on” in intervals of 45 seconds.
When the thermostat is satisfied, each separate load
will be “sequenced off” in intervals of about 45 seconds.
W
R
Fig. 4. Diagram using one thermostat to
operate one Level-Temp. operator
WHITE
RED
SILENT
OPERATOR
L1
L2
LINE
LOAD # 1
YELLOW
BLACK
BLUE
2-WIRE
HEATING
THERMOSTAT
MAKE L2 “HOT”
ON 120V MODELS
Fig. 5. Typical Wiring Diagram to “Sequence” two or more loads
A
B
A
B
A
B
WIRING
Line Voltage
Line Voltage Field
Low Voltage
L1
L2
LOAD # 1
BLACK
BLUE
YELLOW
BLACK
BLUE
YELLOW
BLACK
BLUE
YELLOW
SILENT
OPERATOR # 1
RED
WHITE
RED
WHITE
RED
WHITE
TO LOW VOLTAGE
ROOM THERMOSTAT
NOTE
Use thermostat with a .2A fixed heater,
or set adjustable heater in thermostat
at .2A.
LOAD # 2
SILENT
OPERATOR # 2
L1
L2
FIELD INSTALLED
WIRE NUT
LOAD # 3
SILENT
OPERATOR # 3
L1
L2
TO YELLOW
LEAD OF
ADDITIONAL
LEVEL TEMPS
Leads “A” and “B” must be alternated between
L1 and L2 as shown for each Silent Operator
used.
CAUTION
MAKE L2 “HOT”
ON 120V MODELS