White Rodgers 1hdez-1521 Thermostat User Manual


 
SET-UP
14
EMR(EnergyManagementRecovery)
Default is On. With EMR selected On,
the heating or cooling system will start
early so the temperature in your home
is at the desired temperature at the
beginning of the program period. If set
to Off, the system will not start until
the beginning of the program period.
CycleHumidier – Default if Off. This
feature provides an option that reduc-
es the water usage by up to 50% when
a flow-through humidifier is controlled
by the thermostat. It is recommended
for use on flow-through humidifiers
only. When turned On, the humidifier
will cycle to turn off for 10 minutes
after it has run for 10 minutes. The
blower and/or furnace will continue to
run during the humidifier off period.
AutoHumidityReduction – Default is
Off. When selected, High or Low pro-
vides the ability to minimize or reduce
the window condensation by reducing
the humidity setpoint when the outside
temperature is cold.
ComfortorDehum – Default is Off.
When Comf option is selected the
temperature is altered by the humidity
to reflect the true comfort. When
Dehumis selected humidity reduction
is maximized by continuing to cool
below the temperature setpoint.