White Rodgers 1F87-251 Thermostat User Manual


 
5
5) Select Compressor Lockout LOC OFF or ON - Selecting
LOC ON will cause the thermostat to wait 5 minutes before
turning on the compressor if the heating and cooling system
loses power. It will also wait 5 minutes minimum between
cooling cycles. This is intended to help protect the compres-
sor from short cycling. Some newer compressors already
have a time delay built in and do not require this feature.
Your compressor manufacturer can tell you if the feature is
already present in their system. When the compressor time
delay occurs it will flash the (snowflake icon) for about five
minutes then turn on the compressor.
6) Select Temperature Display Adjustment 4 LO to 4 HI -
Allows you to adjust the room temperature display 4° higher
or lower. Your thermostat was accurately calibrated at the
factory but you have the option to change the display
temperature to match your previous thermostat.
7) Select F° or C° Readout - Changes the display readout to
Centigrade or Fahrenheit as required.
OPERATING FEATURES
Now that you are familiar with the thermostat buttons and
display, read the following information to learn about the many
features of the thermostat.
SIMULTANEOUS HEATING/COOLING PROGRAM
STORAGE When programming, you can enter both your
heating and cooling programs at the same time. There is no
need to reprogram the thermostat at the beginning of each
season.
TEMPERATURE OVERRIDE Press
or until the
display shows the temperature you want. The thermostat
will override current programming and keep the room
temperature at the selected temperature until the next
program period begins. Then the thermostat will automati-
cally revert to the program.
HOLD TEMPERATURE The thermostat can hold any
temperature within its range for an indefinite period without
reverting to the programmed temperature. Momentarily
press HOLD button. "HOLD" will be displayed. Then choose
1
Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS
2
(FA)
SL
4
5
E
(ON)
OFF
6
7
LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
(F) C
Returns to normal operation
8
Select Energy Management Recovery OFF or ON
Select Compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to F or C
RUN
PRGM
and RUN
HOLD
*
HOLD
*
3
d-L
(ON)
OFF
Select display backlight OFF or ON
HOLD
*
HOLD
*
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
HOLD
*
HOLD
*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press
HOLD to advance to next item or TIME to move backwards to previous item
the desired temperature by pressing or . The
thermostat will hold the room temperature at the selected
setting until you press RUN button to start program opera-
tion again.
LOW BATTERY INDICATORIf the 2 AA alkaline bat-
teries are low and should be replaced, the display will be
blank except for LO BATT. When the batteries are low,
pressing any button will cause the display to operate for ten
seconds. After ten seconds, the display will be blank except
for LO BATT. You cannot program with low batteries, but
you can override setpoint temperature. After LO BATT
has been displayed for 4 weeks, the thermostat will raise
the temperature 10 degrees above your setpoint on COOL
mode and will drop temperature 10 degrees below your
setpoint on HEAT mode.
SIMPLIFIED COPY DAY FUNCTION This feature al-
lows Monday's program to be copied into the rest of the
week's programming. This feature is available the first
time you program your thermostat. To use this feature,
simply enter the program for Monday as described in
PROGRAMMING YOUR THERMOSTAT, and then press
RUN or HOLD. The only way to restore this feature is to
complete a software reset (see Reset Operation under
TROUBLESHOOTING section).
COPY DAY FUNCTION This feature allows a selected
day's program to be copied to the desired day's program-
ming. To use this feature: in PRGM mode, select the day
to be copied
from by pressing the HOLD button. Enter the
program for the selected day as described in PROGRAM-
MING YOUR THERMOSTAT. Press and hold the TIME
button for 4 seconds to begin the Copy mode. The LCD will
display "COPY" and the selected day to be copied. The
day the program will copy to will be flashing. Press the
HOLD button to select the day you want to copy to. Press
TIME to complete the Copy Day operation and return to
PRGM mode. Press RUN to exit.