6
OPERAOPERA
OPERAOPERA
OPERA
TING TING
TING TING
TING
YY
YY
Y
OUR OUR
OUR OUR
OUR
THERMOSTTHERMOST
THERMOSTTHERMOST
THERMOST
AA
AA
A
TT
TT
T
Choose the FChoose the F
Choose the FChoose the F
Choose the F
an Setting (Aan Setting (A
an Setting (Aan Setting (A
an Setting (A
uto or On)uto or On)
uto or On)uto or On)
uto or On)
Set the FAN Switch to
AA
AA
A
uto uto
uto uto
uto or
OnOn
OnOn
On.
Fan
AA
AA
A
uto uto
uto uto
uto is the most commonly selected setting and runs
the fan only when the heating or cooling system is on.
Fan
OnOn
OnOn
On runs the fan continuously for increased air circulation
or to allow additional air cleaning.
Choose the System SettingChoose the System Setting
Choose the System SettingChoose the System Setting
Choose the System Setting
(Hea(Hea
(Hea(Hea
(Hea
t,t,
t,t,
t,
Of Of
Of Of
Of
ff
ff
f
,,
,,
,
Cool, Cool,
Cool, Cool,
Cool,
AA
AA
A
utouto
utouto
uto
,,
,,
,
Emer) Emer)
Emer) Emer)
Emer)
Press the SYSTEM button to select:
HeaHea
HeaHea
Hea
tt
tt
t: Thermostat controls only the heating system.
OfOf
OfOf
Of
ff
ff
f: Heating and Cooling systems are off.
CoolCool
CoolCool
Cool: Thermostat controls only the cooling system.
AA
AA
A
utouto
utouto
uto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day.
AA
AA
A
UTUT
UTUT
UT
OO
OO
O allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using
AA
AA
A
UTUT
UTUT
UT
OO
OO
O, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
EmerEmer
EmerEmer
Emer
::
::
: (Heat Pump models) Thermostat controls only backup
heating system.
ManMan
ManMan
Man
ual Operual Oper
ual Operual Oper
ual Oper
aa
aa
a
tion ftion f
tion ftion f
tion f
or Non-Pror Non-Pr
or Non-Pror Non-Pr
or Non-Pr
oo
oo
o
gg
gg
g
rr
rr
r
ammaamma
ammaamma
amma
bb
bb
b
lele
lele
le
ModeMode
ModeMode
Mode
PrPr
PrPr
Pr
ess ess
ess ess
ess the SYSTEM button to select Heat or Cool and use
the
or buttons to adjust the temperature to your
desired setting. After selecting your desired settings you can
also press the SYSTEM button to select
AUTOAUTO
AUTOAUTO
AUTO to allow
the thermostat to automatically change between Heat and
Cool.
ManMan
ManMan
Man
ual Operual Oper
ual Operual Oper
ual Oper
aa
aa
a
tion (Bypassing the Prtion (Bypassing the Pr
tion (Bypassing the Prtion (Bypassing the Pr
tion (Bypassing the Pr
oo
oo
o
gg
gg
g
rr
rr
r
am)am)
am)am)
am)
PrPr
PrPr
Pr
oo
oo
o
gg
gg
g
rr
rr
r
ammaamma
ammaamma
amma
bb
bb
b
le le
le le
le
TT
TT
T
herher
herher
her
mostamosta
mostamosta
mosta
tsts
tsts
ts
Press
or and then the HOLD button and adjust the
temperature wherever you like. This will override the pro-
gram. The
HOLDHOLD
HOLDHOLD
HOLD feature bypasses the program and allows
you to adjust the temperature manually, as needed. What-
ever temperature you set in
HOLDHOLD
HOLDHOLD
HOLD will be maintained 24
hours a day, until you manually change the temperature or
press
RR
RR
R
un Scun Sc
un Scun Sc
un Sc
hedhed
hedhed
hed to cancel
HOLDHOLD
HOLDHOLD
HOLD and resume the pro-
grammed schedule.
PrPr
PrPr
Pr
oo
oo
o
gg
gg
g
rr
rr
r
am Ovam Ov
am Ovam Ov
am Ov
erer
erer
er
ride (Tride (T
ride (Tride (T
ride (T
emporempor
emporempor
empor
arar
arar
ar
y Ovy Ov
y Ovy Ov
y Ov
erer
erer
er
ride)ride)
ride)ride)
ride)
Press
or buttons to adjust the temperature. This will
override the temperature setting until the next programmed
time. To cancel the temporary setting at any time and return
to the program, press
RR
RR
R
un Scun Sc
un Scun Sc
un Sc
hedhed
hedhed
hed. If the SYSTEM button is
pressed to select
AA
AA
A
UTUT
UTUT
UT
OO
OO
O the thermostat will change to Heat
or Cool, whichever ran last. If it switches to heat but you want
cool, or it changes to cool but you want heat, press both
and buttons simultaneously to change to the other
mode.
Set CurSet Cur
Set CurSet Cur
Set Cur
rr
rr
r
ent ent
ent ent
ent
Time and DaTime and Da
Time and DaTime and Da
Time and Da
yy
yy
y
1) Press Menu and then Time button once. The display
will show the hour only.
2) Press and hold either the
or key until you reach
the correct hour and AM/PM designation (AM begins at
midnight, PM begins at noon).
3) Press Time once again. The display window will show
the minutes only.
4) Press and hold either the
or key until you reach
the correct minutes.
5) Press Time once again. The display will show the day
of the week.
6) Press the
or key until you reach the current day
of the week.
7) Press Run to exit the Time mode.
Enter the HeaEnter the Hea
Enter the HeaEnter the Hea
Enter the Hea
ting Prting Pr
ting Prting Pr
ting Pr
oo
oo
o
gg
gg
g
rr
rr
r
amam
amam
am
1) Press SYSTEM button to select "
HeaHea
HeaHea
Hea
tt
tt
t" in the system
switch area indicating the active mode being pro-
grammed.
2) Press the Menu button and then press Schedule.
3) The top of the display will show the day(s) being pro-
grammed. The time and temperature (flashing) are also
displayed. "
11
11
1" will also be displayed to indicate
the period.
4) Press
or key to change the temperature to your
selected temperature for the 1st heating period.
5) Press Time button, time will flash.
6) Press
or key to adjust the start time for the
1st period.
7) The time will change in 15 minute increments.
8) After you have set the time and the temperature for
the period to begin, press Schedule to advance to the
next program period.
9) Repeat steps 2 through 8 until all of the program times
and temperatures are set for all program periods on
that day.
10)Press Schedule to the next day and repeat steps 2
through 9.
11)When programming is complete and all of the times and
temperatures match your desired heating schedule, press
Run Schedule. The thermostat will now run your program.
Enter the Cooling PrEnter the Cooling Pr
Enter the Cooling PrEnter the Cooling Pr
Enter the Cooling Pr
oo
oo
o
gg
gg
g
rr
rr
r
amam
amam
am
1) Press SYSTEM button to select "
CoolCool
CoolCool
Cool" in the system
switch area indicating the active mode being pro-
grammed.
2) Follow
Enter HeaEnter Hea
Enter HeaEnter Hea
Enter Hea
ting Prting Pr
ting Prting Pr
ting Pr
oo
oo
o
gg
gg
g
rr
rr
r
amam
amam
am instructions for entering
cooling times and temperatures.
PRPR
PRPR
PR
OGRAMMING (FOGRAMMING (F
OGRAMMING (FOGRAMMING (F
OGRAMMING (F
or Pror Pr
or Pror Pr
or Pr
oo
oo
o
gg
gg
g
rr
rr
r
ammaamma
ammaamma
amma
bb
bb
b
le Model Onlle Model Onl
le Model Onlle Model Onl
le Model Onl
y)y)
y)y)
y)
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANT!ANT!
ANT!ANT!
ANT!