Cooling System
This thermostat has a built-in short-term (5-minute) time delay.
This feature is activated after the compressor shuts down and
the setpoint is changed within the 5-minute period. During this
5-minute period, COOL will flash on the display indicating that
the thermostat has locked out the compressor to allow head
pressure to stabilize. This thermostat does not sense AC power
loss and therefore does not activate the short term compressor
protection feature when power is restored.
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
10
Alternately displays current time and temperature.
11
BATTERY is displayed when the 3 “AA” batteries are low
and should be replaced. Nothing else will be displayed.
12
Displays currently programmed set temperature (this is
blank when SYSTEM switch is in the OFF position).
13
The word HOLD is displayed when the thermostat is in the
HOLD mode.
OPERATION
Before you begin programming your thermostat, you should be
familiar with its features and with the display and the location and
operation of the thermostat buttons. Your thermostat consists of
two parts: the thermostat cover and the base. To remove the
cover, gently pull it straight out from the base. To replace the
cover, line up the cover with the base and press gently until the
cover snaps onto the base.
THE THERMOSTAT BASE
Other than and , the following buttons and switches are
located behind the door on the bottom of the thermostat cover
(see fig. 11). Pull the door down to open it.
The Thermostat Buttons and Switches
1
(Red arrow) Raises temperature setting.
2
(Blue arrow) Lowers temperature setting.
3
SET TIME button.
4
VIEW PRGM (program) button.
5
RUN PRGM (program) button.
6
HOLD TEMPerature button.
7
FAN switch (ON, AUTO).
8
SYSTEM switch (COOL, OFF, HEAT).
The Display
9
HEAT is displayed when the SYSTEM switch is in the
HEAT position. COOL is displayed (non-flashing) when the
SYSTEM switch is in the COOL position. COOL is dis-
played (flashing) when the compressor is in lockout mode.
CAUTION
!
Figure 11. Thermostat display, buttons, and switches
3
2
1
4 5 6 7 8
AUTOSET TIME VIEW PRGM RUN PRGM HOLD TEMP FAN ON COOL OFF HEAT
HOLD
COOL
BATTERY
AM
HEAT
9
911 1012 13
10
1. Move SYSTEM switch to COOL position.
2. Press
to adjust thermostat setting below room tempera-
ture. The blower should come on immediately on high speed,
followed by cold air circulation
3. Press to adjust temperature setting above room tem-
perature. The cooling system should stop operating.