White Rodgers 1E30(W) Thermostat User Manual


 
3
ATTACHING THERMOSTAT
1. Remove cover from thermostat by gripping the base in
one hand. Use the other hand to pull gently at the top
or bottom of the cover.
2. Carefully remove the shipping protective packing from
the switch.
3. Pull wires through the opening in the thermostat base
and connect wires beneath the terminal screws. (see
Fig. 2 & 3).
4. Push excess wiring back into wall and plug hole with
fire resistant material (such as fiberglass insulation) to
prevent drafts from affecting thermostat operation.
5. Position thermostat base over hole in wall and mark
mounting hole location on wall.
6. Drill mounting hole.
7. Fasten base loosely to wall using mounting screws.
Place a level against the top of the thermostat base,
adjust until level, and tighten mounting screws to
secure base. If holes in wall are too large and do not
allow you to tighten the mounting screws securely, use
plastic exansion plugs.
8. Snap the cover on the thermostat base and set
temperature lever to desired setpoint.
9. Turn on electrical power to the system.
Figure 2. Wiring Diagram
CAUTION
ADJUSTING HEAT ANTICIPATOR
The adjustable heat anticipator WILL BURN OUT
if 25vAC is applied directly to the thermostat
because of incorrect wiring or by shorting out the
primary control during testing. This may cause
personal injury and/or property damage.
This thermostat is equipped with an adjustable heat
anticipator and was preset at the factory to provide
satisfactory operation of the heating system under normal
conditions. If additional adjustments are necessary, they
may be made as follows (see Fig. 4).
1. Remove thermostat cover.
2. If heat cycle is too long, set heat anticipator to a slightly
lower dial setting (1/2 division).
Arrow points to the
matched current rating
of the primary control
Move this lever to
adjust heat
anticipator
Figure 4. Anticipator Adjustment
.
.
.
.
.
.
3. If heat cycle is too short, set heat anticipator to a
slightly higher dial setting (1/2 division).
4. Replace thermostat cover.
ADJUSTMENT & MAINTENANCE
W
R
Heat
Anticipator
(adjustable)
THERMOSTAT
SYSTEM
Hot
24VAC 120VAC
Neutral
Heating
System
Cover
Thermostat
Base
Mounting
screws
Terminal
screws
Figure 3. Parts of Thermostat
20
25
30
10
15
10
15
20
25
30
Thermostat
Base
Cover