Vulcan-Hart VL3GMS Boiler User Manual


 
VL SERIES STEAMERS - GENERAL
Pa
g
e 6 of 88
Gas Steamers
INPUT
(BTU/HR)
MANIFOLD
PRESSURE
(INCHES W.C.)
LINE PRESSURE
(INCHES W.C.)
LOAD
(WATTS)
AMPS
(MAX)
NATURAL PROPANE
MAX
MODEL NAT. PROP. NAT. PROP. RECOMMEND MIN RECOMMEND MIN
120V
60HZ
VL2GPS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL2GMS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL2GAS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL2GSS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL3GPS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL3GMS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL3GAS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
VL3GSS
200,000 200,000
4.0 10.0 7.0 5.0 11.0 11.0 14.0 360 3.0
240,000 240,000
Electric Steamers
AMPERAGE
1 PHASE 3 PHASE 3 PHASE - 4 WIRE
MODEL
TOTAL
KW
208V 240V 208V 240V 480V 220/380V & 240/415V
VL2EPS
24* 116 100 67 58 29 34
36 100 87 44 50
42 117
48 116 58 67
VL2EMS
24* 116 100 67 58 29 34
36 100 87 44 50
42 117
48 116 58 67
VL2ESS
24* 116 100 67 58 29 34
36 100 87 44 50
42 117
48 116 58 67
VL2EAS
24* 116 100 67 58 29 34
36 100 87 44 50
42 117
48 116 58 67
*std