Vulcan-Hart SG6 Gas Heater User Manual


 
Fig. 6
TEMPERATURE PROBE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1. Remove the
RIGHT SIDE PANEL.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the
CONTROL PANEL.
2. Disconnect the probe leads from the solid state
temperature control.
3. Remove the racks and right rack support.
4. Remove the probe guard.
Fig. 7
5. Remove probe by pushing it through the oven
wall and into the control panel area.
Fig. 8
NOTE: The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6. Reverse the procedure to install the replacement
probe.
7. Adjust the temperature control as outlined under
SOLID STATE TEMPERATURE CONTROL
CALIBRATION .
GAS BURNER
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1. Remove the
BOTTOM FRONT COVER.
SG SERIES GAS CONVECTION OVENS - REMOVAL AND REPLACEMENT OF PARTS
F45525 Rev. A (0315) Page 8 of 33