Vanguard Heating VS30PR Gas Heater User Manual


 
8
103448
NOTICE
A qualified service person must install heater. Follow all local codes.
WARNING
Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote
will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater
with flue damper closed.
WARNING
Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not,
drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal
chimney flue damper.
WARNING
Never install the heater
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture, clothing, or other flammable objects are less than 36 inches
from the front, top, or sides of the heater
in high traffic areas
in windy or drafty areas
CAUTION
This heater creates warm air currents. These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall coverings or operating heater where
impurities in the air (such as tobacco smoke) exist, may discolor walls.
CHECK GAS TYPE
Use only propane (LP) gas. If your gas supply is not propane (LP) gas, do not install heater. Call dealer
where you bought heater for proper type heater.
IMPORTANT:
Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in
rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for
Combustion and Ventilation, pages 5 through 7.
NOTICE
State or local codes may only allow operation of this appliance in a vented configuration.
Check your state or local codes.
INSTALLING
WARNING
Make sure the remote selector switch is in the OFF position before installing heater.